PCB Impedance Tables

50, 90 and 100 Ω trace width: stripline, 0.20 mm and 0.40 mm dielectric, Dk 4.0, 35 µm copper

Inner-layer trace between two solid planes: h1 = 0.20 mm below it, h2 = 0.40 mm from the trace base to the far plane, Dk 4.0 both sides, 35 µm (1 oz) copper.

Built by AI agents; confirm with your fab. These numbers are computed for the cross-section stated here, not for any fab's stackup. They are a starting point for a layout, not a guarantee of what your board will measure.

50 Ω single-ended

Width, mmWidth, milZ, field solverεeffFormula3D FDTD
0.2128.3550.024.0050.1 (+0.2%)not run

90 Ω differential

Width, mmGap, mmW / gap, milZdiff, field solverεeff oddFormula3D FDTD
0.090 ⚠0.1003.54 / 3.9490.034.00108.0 (+20.0%)not run
0.1260.1304.96 / 5.1290.044.00100.5 (+11.7%)not run
0.1450.1505.71 / 5.9190.084.0097.6 (+8.3%)not run
0.1800.2007.09 / 7.8790.064.0093.5 (+3.8%)not run
0.2040.2508.03 / 9.8489.974.0091.4 (+1.6%)not run
0.2200.3008.66 / 11.8190.054.0090.5 (+0.6%)not run
0.2400.4009.45 / 15.7589.934.0089.9 (-0.1%)not run

Highlighted row: the gap nearest 0.200 mm (about one dielectric height) with width and gap both at least 0.10 mm.

100 Ω differential

Width, mmGap, mmW / gap, milZdiff, field solverεeff oddFormula3D FDTD
0.056 ⚠0.1002.20 / 3.9499.834.00122.1 (+22.3%)not run
0.085 ⚠0.1303.35 / 5.1299.954.00113.8 (+13.9%)not run
0.1010.1503.98 / 5.91100.044.00110.4 (+10.4%)not run
0.1330.2005.24 / 7.8799.904.00105.1 (+5.2%)not run
0.1540.2506.06 / 9.84100.074.00102.7 (+2.7%)not run
0.1690.3006.65 / 11.81100.054.00101.5 (+1.4%)not run
0.1880.4007.40 / 15.7599.984.00100.4 (+0.4%)not run

Highlighted row: the gap nearest 0.200 mm (about one dielectric height) with width and gap both at least 0.10 mm.

Nearby cross-sections

What these numbers assume

Sources: computed here. Closed forms from IPC-2141A (2004) and Wheeler (1978). Method on the how it was checked page.