50, 90 and 100 Ω trace width: stripline, 0.20 mm and 0.40 mm dielectric, Dk 4.0, 18 µm copper

Inner-layer trace between two solid planes: h1 = 0.20 mm below it, h2 = 0.40 mm from the trace base to the far plane, Dk 4.0 both sides, 18 µm (½ oz) copper.

Built by AI agents; confirm with your fab. These numbers are computed for the cross-section stated here, not for any fab's stackup. They are a starting point for a layout, not a guarantee of what your board will measure.

50 Ω single-ended

Width, mmWidth, milZ, field solverεeffFormula3D FDTD
0.2359.2550.034.0050.2 (+0.3%)not run

90 Ω differential

Width, mmGap, mmW / gap, milZdiff, field solverεeff oddFormula3D FDTD
0.1340.1005.28 / 3.9489.904.00100.8 (+12.1%)not run
0.1660.1306.54 / 5.1290.044.0095.9 (+6.5%)not run
0.1840.1507.24 / 5.9189.904.0093.7 (+4.2%)not run
0.2140.2008.43 / 7.8790.094.0091.2 (+1.2%)not run
0.2350.2509.25 / 9.8489.974.0090.0 (+0.0%)not run
0.2490.3009.80 / 11.8190.074.0089.6 (-0.5%)not run
0.2660.40010.47 / 15.7590.084.0089.6 (-0.6%)not run

Highlighted row: the gap nearest 0.200 mm (about one dielectric height) with width and gap both at least 0.10 mm.

100 Ω differential

Width, mmGap, mmW / gap, milZdiff, field solverεeff oddFormula3D FDTD
0.093 ⚠0.1003.66 / 3.94100.024.00114.6 (+14.5%)not run
0.1210.1304.76 / 5.1299.984.00108.5 (+8.6%)not run
0.1360.1505.35 / 5.9199.994.00106.1 (+6.1%)not run
0.1640.2006.46 / 7.87100.094.00102.7 (+2.6%)not run
0.1840.2507.24 / 9.8499.934.00100.9 (+1.0%)not run
0.1980.3007.80 / 11.8199.914.00100.0 (+0.1%)not run
0.2140.4008.43 / 15.7599.954.0099.8 (-0.2%)not run

Highlighted row: the gap nearest 0.200 mm (about one dielectric height) with width and gap both at least 0.10 mm.

Nearby cross-sections

What these numbers assume

Sources: computed here. Closed forms from IPC-2141A (2004) and Wheeler (1978). Method on the how it was checked page.