50, 90 and 100 Ω trace width: stripline, 0.15 mm and 0.40 mm dielectric, Dk 4.0, 35 µm copper

Inner-layer trace between two solid planes: h1 = 0.15 mm below it, h2 = 0.40 mm from the trace base to the far plane, Dk 4.0 both sides, 35 µm (1 oz) copper.

Built by AI agents; confirm with your fab. These numbers are computed for the cross-section stated here, not for any fab's stackup. They are a starting point for a layout, not a guarantee of what your board will measure.

50 Ω single-ended

Width, mmWidth, milZ, field solverεeffFormula3D FDTD
0.1656.5050.064.0050.7 (+1.3%)not run

90 Ω differential

Width, mmGap, mmW / gap, milZdiff, field solverεeff oddFormula3D FDTD
0.081 ⚠0.1003.19 / 3.9489.984.00104.6 (+16.2%)not run
0.1100.1304.33 / 5.1290.004.0098.2 (+9.1%)not run
0.1250.1504.92 / 5.9189.954.0095.7 (+6.4%)not run
0.1510.2005.94 / 7.8790.084.0092.6 (+2.8%)not run
0.1680.2506.61 / 9.8490.054.0091.3 (+1.3%)not run
0.1790.3007.05 / 11.8190.104.0090.8 (+0.8%)not run
0.1930.4007.60 / 15.7590.014.0090.5 (+0.5%)not run

Highlighted row: the gap nearest 0.150 mm (about one dielectric height) with width and gap both at least 0.10 mm.

100 Ω differential

Width, mmGap, mmW / gap, milZdiff, field solverεeff oddFormula3D FDTD
0.051 ⚠0.1002.01 / 3.9499.884.00118.2 (+18.3%)not run
0.075 ⚠0.1302.95 / 5.1299.954.00111.0 (+11.0%)not run
0.088 ⚠0.1503.46 / 5.9199.924.00108.0 (+8.1%)not run
0.1120.2004.41 / 7.8799.974.00103.9 (+4.0%)not run
0.1270.2505.00 / 9.84100.124.00102.4 (+2.2%)not run
0.1380.3005.43 / 11.8199.974.00101.5 (+1.5%)not run
0.1510.4005.94 / 15.75100.004.00100.9 (+0.9%)not run

Highlighted row: the gap nearest 0.150 mm (about one dielectric height) with width and gap both at least 0.10 mm.

Nearby cross-sections

What these numbers assume

Sources: computed here. Closed forms from IPC-2141A (2004) and Wheeler (1978). Method on the how it was checked page.