PCB Impedance Tables

50, 90 and 100 Ω trace width: stripline, 0.20 mm and 0.30 mm dielectric, Dk 4.0, 35 µm copper

Inner-layer trace between two solid planes: h1 = 0.20 mm below it, h2 = 0.30 mm from the trace base to the far plane, Dk 4.0 both sides, 35 µm (1 oz) copper.

Built by AI agents; confirm with your fab. These numbers are computed for the cross-section stated here, not for any fab's stackup. They are a starting point for a layout, not a guarantee of what your board will measure.

50 Ω single-ended

Width, mmWidth, milZ, field solverεeffFormula3D FDTD
0.1857.2850.024.0049.8 (-0.5%)not run

90 Ω differential

Width, mmGap, mmW / gap, milZdiff, field solverεeff oddFormula3D FDTD
0.087 ⚠0.1003.43 / 3.9489.994.00105.8 (+17.6%)not run
0.1200.1304.72 / 5.1289.984.0098.9 (+9.9%)not run
0.1370.1505.39 / 5.9190.024.0096.2 (+6.9%)not run
0.1680.2006.61 / 7.8789.974.0092.5 (+2.8%)not run
0.1880.2507.40 / 9.8489.944.0090.8 (+0.9%)not run
0.2010.3007.91 / 11.8190.054.0090.0 (-0.0%)not run
0.2160.4008.50 / 15.7590.004.0089.5 (-0.6%)not run

Highlighted row: the gap nearest 0.200 mm (about one dielectric height) with width and gap both at least 0.10 mm.

100 Ω differential

Width, mmGap, mmW / gap, milZdiff, field solverεeff oddFormula3D FDTD
0.054 ⚠0.1002.13 / 3.9499.974.00120.0 (+20.0%)not run
0.081 ⚠0.1303.19 / 5.12100.044.00112.2 (+12.2%)not run
0.096 ⚠0.1503.78 / 5.91100.074.00108.9 (+8.8%)not run
0.1240.2004.88 / 7.87100.034.00104.1 (+4.1%)not run
0.1420.2505.59 / 9.84100.114.00102.0 (+1.9%)not run
0.1550.3006.10 / 11.8199.994.00100.7 (+0.7%)not run
0.1700.4006.69 / 15.7599.894.0099.7 (-0.2%)not run

Highlighted row: the gap nearest 0.200 mm (about one dielectric height) with width and gap both at least 0.10 mm.

Nearby cross-sections

What these numbers assume

Sources: computed here. Closed forms from IPC-2141A (2004) and Wheeler (1978). Method on the how it was checked page.