PCB Impedance Tables

50, 90 and 100 Ω trace width: stripline, 0.20 mm and 0.50 mm dielectric, Dk 4.0, 35 µm copper

Inner-layer trace between two solid planes: h1 = 0.20 mm below it, h2 = 0.50 mm from the trace base to the far plane, Dk 4.0 both sides, 35 µm (1 oz) copper.

Built by AI agents; confirm with your fab. These numbers are computed for the cross-section stated here, not for any fab's stackup. They are a starting point for a layout, not a guarantee of what your board will measure.

50 Ω single-ended

Width, mmWidth, milZ, field solverεeffFormula3D FDTD
0.2299.0250.044.0050.6 (+1.1%)not run

90 Ω differential

Width, mmGap, mmW / gap, milZdiff, field solverεeff oddFormula3D FDTD
0.091 ⚠0.1003.58 / 3.9490.114.00109.5 (+21.5%)not run
0.1290.1305.08 / 5.1289.974.00101.5 (+12.8%)not run
0.1490.1505.87 / 5.9190.064.0098.3 (+9.2%)not run
0.1860.2007.32 / 7.8790.054.0094.0 (+4.4%)not run
0.2120.2508.35 / 9.8489.984.0091.9 (+2.1%)not run
0.2300.3009.06 / 11.8190.034.0090.9 (+1.0%)not run
0.2520.4009.92 / 15.7590.084.0090.4 (+0.3%)not run

Highlighted row: the gap nearest 0.200 mm (about one dielectric height) with width and gap both at least 0.10 mm.

100 Ω differential

Width, mmGap, mmW / gap, milZdiff, field solverεeff oddFormula3D FDTD
0.056 ⚠0.1002.20 / 3.94100.074.00123.8 (+23.7%)not run
0.086 ⚠0.1303.39 / 5.12100.064.00115.1 (+15.1%)not run
0.1030.1504.06 / 5.91100.074.00111.4 (+11.3%)not run
0.1360.2005.35 / 7.87100.104.00106.0 (+5.9%)not run
0.1600.2506.30 / 9.84100.004.00103.2 (+3.2%)not run
0.1760.3006.93 / 11.81100.044.00102.0 (+2.0%)not run
0.1980.4007.80 / 15.7599.924.00100.8 (+0.9%)not run

Highlighted row: the gap nearest 0.200 mm (about one dielectric height) with width and gap both at least 0.10 mm.

Nearby cross-sections

What these numbers assume

Sources: computed here. Closed forms from IPC-2141A (2004) and Wheeler (1978). Method on the how it was checked page.