PCB Impedance Tables

50, 90 and 100 Ω trace width: stripline, 0.15 mm and 0.50 mm dielectric, Dk 3.5, 18 µm copper

Inner-layer trace between two solid planes: h1 = 0.15 mm below it, h2 = 0.50 mm from the trace base to the far plane, Dk 3.5 both sides, 18 µm (½ oz) copper.

Built by AI agents; confirm with your fab. These numbers are computed for the cross-section stated here, not for any fab's stackup. They are a starting point for a layout, not a guarantee of what your board will measure.

50 Ω single-ended

Width, mmWidth, milZ, field solverεeffFormula3D FDTD
0.2238.7850.023.5051.4 (+2.7%)not run

90 Ω differential

Width, mmGap, mmW / gap, milZdiff, field solverεeff oddFormula3D FDTD
0.1460.1005.75 / 3.9490.013.5097.5 (+8.3%)not run
0.1740.1306.85 / 5.1290.033.5093.4 (+3.8%)not run
0.1880.1507.40 / 5.9190.063.5091.9 (+2.1%)not run
0.2130.2008.39 / 7.8790.033.5090.2 (+0.2%)not run
0.2290.2509.02 / 9.8490.073.5089.8 (-0.3%)not run
0.2400.3009.45 / 11.8190.063.5089.8 (-0.2%)not run
0.2540.40010.00 / 15.7590.033.5090.3 (+0.3%)not run

Highlighted row: the gap nearest 0.150 mm (about one dielectric height) with width and gap both at least 0.10 mm.

100 Ω differential

Width, mmGap, mmW / gap, milZdiff, field solverεeff oddFormula3D FDTD
0.1060.1004.17 / 3.94100.083.50110.7 (+10.6%)not run
0.1310.1305.16 / 5.12100.093.50105.6 (+5.5%)not run
0.1440.1505.67 / 5.91100.033.50103.7 (+3.6%)not run
0.1670.2006.57 / 7.87100.073.50101.3 (+1.3%)not run
0.1830.2507.20 / 9.8499.883.50100.4 (+0.5%)not run
0.1930.3007.60 / 11.8199.963.50100.3 (+0.4%)not run
0.2060.4008.11 / 15.7599.983.50100.7 (+0.7%)not run

Highlighted row: the gap nearest 0.150 mm (about one dielectric height) with width and gap both at least 0.10 mm.

Nearby cross-sections

What these numbers assume

Sources: computed here. Closed forms from IPC-2141A (2004) and Wheeler (1978). Method on the how it was checked page.