PCB Impedance Tables

50, 90 and 100 Ω trace width: stripline, 0.20 mm and 0.50 mm dielectric, Dk 3.5, 18 µm copper

Inner-layer trace between two solid planes: h1 = 0.20 mm below it, h2 = 0.50 mm from the trace base to the far plane, Dk 3.5 both sides, 18 µm (½ oz) copper.

Built by AI agents; confirm with your fab. These numbers are computed for the cross-section stated here, not for any fab's stackup. They are a starting point for a layout, not a guarantee of what your board will measure.

50 Ω single-ended

Width, mmWidth, milZ, field solverεeffFormula3D FDTD
0.28711.3049.983.5050.6 (+1.2%)not run

90 Ω differential

Width, mmGap, mmW / gap, milZdiff, field solverεeff oddFormula3D FDTD
0.1670.1006.57 / 3.9490.003.50100.5 (+11.7%)not run
0.2040.1308.03 / 5.1289.953.5095.4 (+6.0%)not run
0.2230.1508.78 / 5.9190.043.5093.4 (+3.7%)not run
0.2580.20010.16 / 7.8789.993.5090.7 (+0.8%)not run
0.2810.25011.06 / 9.8489.993.5089.7 (-0.3%)not run
0.2980.30011.73 / 11.8189.943.5089.3 (-0.7%)not run
0.3180.40012.52 / 15.7589.983.5089.5 (-0.6%)not run

Highlighted row: the gap nearest 0.200 mm (about one dielectric height) with width and gap both at least 0.10 mm.

100 Ω differential

Width, mmGap, mmW / gap, milZdiff, field solverεeff oddFormula3D FDTD
0.1190.1004.69 / 3.94100.033.50114.4 (+14.4%)not run
0.1510.1305.94 / 5.12100.053.50108.3 (+8.2%)not run
0.1690.1506.65 / 5.9199.963.50105.6 (+5.6%)not run
0.2010.2007.91 / 7.8799.953.50102.1 (+2.2%)not run
0.2220.2508.74 / 9.84100.063.50100.8 (+0.8%)not run
0.2380.3009.37 / 11.81100.033.50100.1 (+0.1%)not run
0.2570.40010.12 / 15.75100.093.50100.0 (-0.1%)not run

Highlighted row: the gap nearest 0.200 mm (about one dielectric height) with width and gap both at least 0.10 mm.

Nearby cross-sections

What these numbers assume

Sources: computed here. Closed forms from IPC-2141A (2004) and Wheeler (1978). Method on the how it was checked page.