PCB Impedance Tables

50, 90 and 100 Ω trace width: stripline, 0.10 mm and 0.50 mm dielectric, Dk 3.5, 18 µm copper

Inner-layer trace between two solid planes: h1 = 0.10 mm below it, h2 = 0.50 mm from the trace base to the far plane, Dk 3.5 both sides, 18 µm (½ oz) copper.

Built by AI agents; confirm with your fab. These numbers are computed for the cross-section stated here, not for any fab's stackup. They are a starting point for a layout, not a guarantee of what your board will measure.

50 Ω single-ended

Width, mmWidth, milZ, field solverεeffFormula3D FDTD
0.1515.9450.013.5052.5 (+5.0%)not run

90 Ω differential

Width, mmGap, mmW / gap, milZdiff, field solverεeff oddFormula3D FDTD
0.1150.1004.53 / 3.9490.013.5093.8 (+4.2%)not run
0.1330.1305.24 / 5.1289.873.5091.0 (+1.3%)not run
0.1410.1505.55 / 5.9190.043.5090.4 (+0.4%)not run
0.1550.2006.10 / 7.8790.123.5090.0 (-0.2%)not run
0.1650.2506.50 / 9.8489.883.5090.0 (+0.1%)not run
0.1700.3006.69 / 11.8190.123.5090.8 (+0.8%)not run
0.1770.4006.97 / 15.7590.133.5091.9 (+2.0%)not run

Highlighted row: the gap nearest 0.130 mm (about one dielectric height) with width and gap both at least 0.10 mm.

100 Ω differential

Width, mmGap, mmW / gap, milZdiff, field solverεeff oddFormula3D FDTD
0.085 ⚠0.1003.35 / 3.94100.163.50106.1 (+6.0%)not run
0.1020.1304.02 / 5.1299.833.50102.3 (+2.5%)not run
0.1100.1504.33 / 5.9199.823.50101.2 (+1.4%)not run
0.1230.2004.84 / 7.8799.923.50100.5 (+0.6%)not run
0.1310.2505.16 / 9.84100.073.50100.8 (+0.7%)not run
0.1370.3005.39 / 11.8199.903.50101.2 (+1.3%)not run
0.1430.4005.63 / 15.75100.083.50102.5 (+2.4%)not run

Highlighted row: the gap nearest 0.130 mm (about one dielectric height) with width and gap both at least 0.10 mm.

Nearby cross-sections

What these numbers assume

Sources: computed here. Closed forms from IPC-2141A (2004) and Wheeler (1978). Method on the how it was checked page.