PCB Impedance Tables

50, 90 and 100 Ω trace width: stripline, 0.15 mm and 0.40 mm dielectric, Dk 3.5, 18 µm copper

Inner-layer trace between two solid planes: h1 = 0.15 mm below it, h2 = 0.40 mm from the trace base to the far plane, Dk 3.5 both sides, 18 µm (½ oz) copper.

Built by AI agents; confirm with your fab. These numbers are computed for the cross-section stated here, not for any fab's stackup. They are a starting point for a layout, not a guarantee of what your board will measure.

50 Ω single-ended

Width, mmWidth, milZ, field solverεeffFormula3D FDTD
0.2128.3550.063.5050.8 (+1.5%)not run

90 Ω differential

Width, mmGap, mmW / gap, milZdiff, field solverεeff oddFormula3D FDTD
0.1440.1005.67 / 3.9490.083.5096.9 (+7.6%)not run
0.1720.1306.77 / 5.1289.933.5092.9 (+3.3%)not run
0.1850.1507.28 / 5.9190.033.5091.6 (+1.8%)not run
0.2090.2008.23 / 7.8789.933.5090.0 (+0.0%)not run
0.2240.2508.82 / 9.8489.933.5089.6 (-0.4%)not run
0.2340.3009.21 / 11.8189.923.5089.6 (-0.4%)not run
0.2460.4009.69 / 15.7589.943.5090.0 (+0.0%)not run

Highlighted row: the gap nearest 0.150 mm (about one dielectric height) with width and gap both at least 0.10 mm.

100 Ω differential

Width, mmGap, mmW / gap, milZdiff, field solverεeff oddFormula3D FDTD
0.1050.1004.13 / 3.94100.093.50110.0 (+9.9%)not run
0.1300.1305.12 / 5.1299.943.50105.0 (+5.1%)not run
0.1420.1505.59 / 5.9199.993.50103.3 (+3.3%)not run
0.1640.2006.46 / 7.87100.053.50101.2 (+1.1%)not run
0.1780.2507.01 / 9.84100.103.50100.5 (+0.4%)not run
0.1880.3007.40 / 11.8199.973.50100.2 (+0.2%)not run
0.1990.4007.83 / 15.75100.113.50100.5 (+0.4%)not run

Highlighted row: the gap nearest 0.150 mm (about one dielectric height) with width and gap both at least 0.10 mm.

Nearby cross-sections

What these numbers assume

Sources: computed here. Closed forms from IPC-2141A (2004) and Wheeler (1978). Method on the how it was checked page.