PCB Impedance Tables

50, 90 and 100 Ω trace width: stripline, 0.15 mm and 0.60 mm dielectric, Dk 3.5, 18 µm copper

Inner-layer trace between two solid planes: h1 = 0.15 mm below it, h2 = 0.60 mm from the trace base to the far plane, Dk 3.5 both sides, 18 µm (½ oz) copper.

Built by AI agents; confirm with your fab. These numbers are computed for the cross-section stated here, not for any fab's stackup. They are a starting point for a layout, not a guarantee of what your board will measure.

50 Ω single-ended

Width, mmWidth, milZ, field solverεeffFormula3D FDTD
0.2309.0650.023.5051.9 (+3.7%)not run

90 Ω differential

Width, mmGap, mmW / gap, milZdiff, field solverεeff oddFormula3D FDTD
0.1470.1005.79 / 3.9489.983.5097.9 (+8.8%)not run
0.1750.1306.89 / 5.1290.083.5093.7 (+4.0%)not run
0.1900.1507.48 / 5.9189.983.5091.9 (+2.2%)not run
0.2150.2008.46 / 7.8790.093.5090.2 (+0.1%)not run
0.2320.2509.13 / 9.8490.073.5089.7 (-0.4%)not run
0.2440.3009.61 / 11.8189.993.5089.7 (-0.4%)not run
0.2590.40010.20 / 15.7589.973.5090.2 (+0.3%)not run

Highlighted row: the gap nearest 0.150 mm (about one dielectric height) with width and gap both at least 0.10 mm.

100 Ω differential

Width, mmGap, mmW / gap, milZdiff, field solverεeff oddFormula3D FDTD
0.1070.1004.21 / 3.9499.923.50110.9 (+11.0%)not run
0.1320.1305.20 / 5.12100.033.50105.8 (+5.7%)not run
0.1450.1505.71 / 5.91100.053.50103.8 (+3.7%)not run
0.1690.2006.65 / 7.8799.973.50101.2 (+1.2%)not run
0.1850.2507.28 / 9.8499.913.50100.3 (+0.4%)not run
0.1950.3007.68 / 11.81100.103.50100.4 (+0.3%)not run
0.2090.4008.23 / 15.75100.093.50100.9 (+0.8%)not run

Highlighted row: the gap nearest 0.150 mm (about one dielectric height) with width and gap both at least 0.10 mm.

Nearby cross-sections

What these numbers assume

Sources: computed here. Closed forms from IPC-2141A (2004) and Wheeler (1978). Method on the how it was checked page.