PCB Impedance Tables

50, 90 and 100 Ω trace width: stripline, 0.15 mm and 0.40 mm dielectric, Dk 4.0, 18 µm copper

Inner-layer trace between two solid planes: h1 = 0.15 mm below it, h2 = 0.40 mm from the trace base to the far plane, Dk 4.0 both sides, 18 µm (½ oz) copper.

Built by AI agents; confirm with your fab. These numbers are computed for the cross-section stated here, not for any fab's stackup. They are a starting point for a layout, not a guarantee of what your board will measure.

50 Ω single-ended

Width, mmWidth, milZ, field solverεeffFormula3D FDTD
0.1867.3249.944.0050.7 (+1.6%)49.9 (-0.0%)

90 Ω differential

Width, mmGap, mmW / gap, milZdiff, field solverεeff oddFormula3D FDTD
0.1190.1004.69 / 3.9489.934.0098.1 (+9.1%)not run
0.1440.1305.67 / 5.1290.064.0094.1 (+4.5%)not run
0.1570.1506.18 / 5.9190.044.0092.5 (+2.7%)not run
0.1800.2007.09 / 7.8789.954.0090.6 (+0.7%)not run
0.1940.2507.64 / 9.8490.074.0090.2 (+0.1%)not run
0.2040.3008.03 / 11.8189.994.0090.0 (+0.0%)not run
0.2160.4008.50 / 15.7589.944.0090.2 (+0.3%)not run

Highlighted row: the gap nearest 0.150 mm (about one dielectric height) with width and gap both at least 0.10 mm.

100 Ω differential

Width, mmGap, mmW / gap, milZdiff, field solverεeff oddFormula3D FDTD
0.084 ⚠0.1003.31 / 3.94100.034.00111.2 (+11.2%)not run
0.1060.1304.17 / 5.12100.144.00106.4 (+6.2%)not run
0.1180.1504.65 / 5.91100.054.00104.3 (+4.2%)not run
0.1390.2005.47 / 7.87100.044.00101.8 (+1.7%)not run
0.1530.2506.02 / 9.8499.944.00100.7 (+0.8%)not run
0.1620.3006.38 / 11.8199.964.00100.5 (+0.6%)not run
0.1730.4006.81 / 15.75100.004.00100.6 (+0.6%)not run

Highlighted row: the gap nearest 0.150 mm (about one dielectric height) with width and gap both at least 0.10 mm.

Nearby cross-sections

What these numbers assume

Sources: computed here. Closed forms from IPC-2141A (2004) and Wheeler (1978). Method on the how it was checked page.