PCB Impedance Tables

50, 90 and 100 Ω trace width: stripline, 0.15 mm and 0.50 mm dielectric, Dk 4.0, 18 µm copper

Inner-layer trace between two solid planes: h1 = 0.15 mm below it, h2 = 0.50 mm from the trace base to the far plane, Dk 4.0 both sides, 18 µm (½ oz) copper.

Built by AI agents; confirm with your fab. These numbers are computed for the cross-section stated here, not for any fab's stackup. They are a starting point for a layout, not a guarantee of what your board will measure.

50 Ω single-ended

Width, mmWidth, milZ, field solverεeffFormula3D FDTD
0.1957.6849.994.0051.4 (+2.8%)not run

90 Ω differential

Width, mmGap, mmW / gap, milZdiff, field solverεeff oddFormula3D FDTD
0.1200.1004.72 / 3.9489.984.0098.8 (+9.8%)not run
0.1460.1305.75 / 5.1290.024.0094.5 (+4.9%)not run
0.1600.1506.30 / 5.9189.904.0092.6 (+3.0%)not run
0.1830.2007.20 / 7.8790.074.0090.9 (+0.9%)not run
0.1990.2507.83 / 9.8489.994.0090.2 (+0.2%)not run
0.2090.3008.23 / 11.8190.104.0090.3 (+0.2%)not run
0.2230.4008.78 / 15.7589.974.0090.5 (+0.6%)not run

Highlighted row: the gap nearest 0.150 mm (about one dielectric height) with width and gap both at least 0.10 mm.

100 Ω differential

Width, mmGap, mmW / gap, milZdiff, field solverεeff oddFormula3D FDTD
0.085 ⚠0.1003.35 / 3.9499.924.00111.8 (+11.8%)not run
0.1080.1304.25 / 5.1299.914.00106.5 (+6.6%)not run
0.1200.1504.72 / 5.9199.914.00104.4 (+4.5%)not run
0.1420.2005.59 / 7.8799.894.00101.8 (+1.9%)not run
0.1560.2506.14 / 9.84100.014.00101.0 (+1.0%)not run
0.1660.3006.54 / 11.8199.974.00100.7 (+0.8%)not run
0.1780.4007.01 / 15.75100.104.00101.1 (+1.0%)not run

Highlighted row: the gap nearest 0.150 mm (about one dielectric height) with width and gap both at least 0.10 mm.

Nearby cross-sections

What these numbers assume

Sources: computed here. Closed forms from IPC-2141A (2004) and Wheeler (1978). Method on the how it was checked page.