PCB Impedance Tables

50, 90 and 100 Ω trace width: stripline, 0.15 mm and 0.30 mm dielectric, Dk 4.0, 18 µm copper

Inner-layer trace between two solid planes: h1 = 0.15 mm below it, h2 = 0.30 mm from the trace base to the far plane, Dk 4.0 both sides, 18 µm (½ oz) copper.

Built by AI agents; confirm with your fab. These numbers are computed for the cross-section stated here, not for any fab's stackup. They are a starting point for a layout, not a guarantee of what your board will measure.

50 Ω single-ended

Width, mmWidth, milZ, field solverεeffFormula3D FDTD
0.1706.6950.014.0050.2 (+0.3%)not run

90 Ω differential

Width, mmGap, mmW / gap, milZdiff, field solverεeff oddFormula3D FDTD
0.1160.1004.57 / 3.9489.974.0097.0 (+7.8%)not run
0.1400.1305.51 / 5.1289.924.0093.2 (+3.6%)not run
0.1520.1505.98 / 5.9189.904.0091.7 (+2.0%)not run
0.1720.2006.77 / 7.8789.964.0090.2 (+0.3%)not run
0.1850.2507.28 / 9.8489.874.0089.6 (-0.3%)not run
0.1920.3007.56 / 11.8190.104.0089.8 (-0.4%)not run
0.2020.4007.95 / 15.7589.934.0089.7 (-0.3%)not run

Highlighted row: the gap nearest 0.150 mm (about one dielectric height) with width and gap both at least 0.10 mm.

100 Ω differential

Width, mmGap, mmW / gap, milZdiff, field solverεeff oddFormula3D FDTD
0.082 ⚠0.1003.23 / 3.94100.164.00110.2 (+10.0%)not run
0.1040.1304.09 / 5.1299.864.00105.2 (+5.3%)not run
0.1150.1504.53 / 5.9199.864.00103.3 (+3.5%)not run
0.1340.2005.28 / 7.8799.894.00101.0 (+1.2%)not run
0.1460.2505.75 / 9.8499.874.00100.2 (+0.3%)not run
0.1530.3006.02 / 11.81100.074.00100.1 (+0.0%)not run
0.1620.4006.38 / 15.75100.034.0099.9 (-0.1%)not run

Highlighted row: the gap nearest 0.150 mm (about one dielectric height) with width and gap both at least 0.10 mm.

Nearby cross-sections

What these numbers assume

Sources: computed here. Closed forms from IPC-2141A (2004) and Wheeler (1978). Method on the how it was checked page.