PCB Impedance Tables

50, 90 and 100 Ω trace width: stripline, 0.20 mm and 0.30 mm dielectric, Dk 4.0, 18 µm copper

Inner-layer trace between two solid planes: h1 = 0.20 mm below it, h2 = 0.30 mm from the trace base to the far plane, Dk 4.0 both sides, 18 µm (½ oz) copper.

Built by AI agents; confirm with your fab. These numbers are computed for the cross-section stated here, not for any fab's stackup. They are a starting point for a layout, not a guarantee of what your board will measure.

50 Ω single-ended

Width, mmWidth, milZ, field solverεeffFormula3D FDTD
0.2108.2750.024.0049.8 (-0.5%)not run

90 Ω differential

Width, mmGap, mmW / gap, milZdiff, field solverεeff oddFormula3D FDTD
0.1290.1005.08 / 3.9490.034.0099.2 (+10.2%)not run
0.1590.1306.26 / 5.1290.004.0094.6 (+5.1%)not run
0.1740.1506.85 / 5.9190.104.0092.9 (+3.1%)not run
0.2010.2007.91 / 7.8790.104.0090.6 (+0.6%)not run
0.2190.2508.62 / 9.8489.934.0089.6 (-0.4%)not run
0.2310.3009.09 / 11.8189.934.0089.1 (-0.9%)not run
0.2440.4009.61 / 15.7589.964.0089.1 (-0.9%)not run

Highlighted row: the gap nearest 0.200 mm (about one dielectric height) with width and gap both at least 0.10 mm.

100 Ω differential

Width, mmGap, mmW / gap, milZdiff, field solverεeff oddFormula3D FDTD
0.091 ⚠0.1003.58 / 3.9499.874.00112.5 (+12.6%)not run
0.1160.1304.57 / 5.12100.084.00107.3 (+7.2%)not run
0.1300.1505.12 / 5.91100.044.00105.0 (+4.9%)not run
0.1560.2006.14 / 7.8799.894.00101.6 (+1.7%)not run
0.1720.2506.77 / 9.84100.044.00100.4 (+0.3%)not run
0.1830.3007.20 / 11.81100.034.0099.8 (-0.3%)not run
0.1960.4007.72 / 15.75100.034.0099.4 (-0.6%)not run

Highlighted row: the gap nearest 0.200 mm (about one dielectric height) with width and gap both at least 0.10 mm.

Nearby cross-sections

What these numbers assume

Sources: computed here. Closed forms from IPC-2141A (2004) and Wheeler (1978). Method on the how it was checked page.