PCB Impedance Tables

50, 90 and 100 Ω trace width: stripline, 0.15 mm and 0.50 mm dielectric, Dk 4.5, 35 µm copper

Inner-layer trace between two solid planes: h1 = 0.15 mm below it, h2 = 0.50 mm from the trace base to the far plane, Dk 4.5 both sides, 35 µm (1 oz) copper.

Built by AI agents; confirm with your fab. These numbers are computed for the cross-section stated here, not for any fab's stackup. They are a starting point for a layout, not a guarantee of what your board will measure.

50 Ω single-ended

Width, mmWidth, milZ, field solverεeffFormula3D FDTD
0.1536.0249.984.5051.2 (+2.5%)not run

90 Ω differential

Width, mmGap, mmW / gap, milZdiff, field solverεeff oddFormula3D FDTD
0.064 ⚠0.1002.52 / 3.9489.914.50106.4 (+18.3%)not run
0.091 ⚠0.1303.58 / 5.1289.904.5099.7 (+10.9%)not run
0.1050.1504.13 / 5.9190.024.5097.1 (+7.8%)not run
0.1310.2005.16 / 7.8790.104.5093.5 (+3.8%)not run
0.1490.2505.87 / 9.8489.944.5091.8 (+2.1%)not run
0.1610.3006.34 / 11.8189.894.5091.2 (+1.4%)not run
0.1750.4006.89 / 15.7590.084.5091.1 (+1.2%)not run

Highlighted row: the gap nearest 0.150 mm (about one dielectric height) with width and gap both at least 0.10 mm.

100 Ω differential

Width, mmGap, mmW / gap, milZdiff, field solverεeff oddFormula3D FDTD
0.059 ⚠0.1302.32 / 5.1299.994.50112.5 (+12.5%)not run
0.071 ⚠0.1502.80 / 5.91100.024.50109.4 (+9.4%)not run
0.094 ⚠0.2003.70 / 7.8799.994.50105.0 (+5.0%)not run
0.1100.2504.33 / 9.8499.974.50103.0 (+3.0%)not run
0.1210.3004.76 / 11.8199.964.50102.1 (+2.1%)not run
0.1340.4005.28 / 15.75100.094.50101.8 (+1.7%)not run

Highlighted row: the gap nearest 0.150 mm (about one dielectric height) with width and gap both at least 0.10 mm.

Nearby cross-sections

What these numbers assume

Sources: computed here. Closed forms from IPC-2141A (2004) and Wheeler (1978). Method on the how it was checked page.