PCB Impedance Tables

50, 90 and 100 Ω trace width: stripline, 0.15 mm and 0.60 mm dielectric, Dk 4.5, 35 µm copper

Inner-layer trace between two solid planes: h1 = 0.15 mm below it, h2 = 0.60 mm from the trace base to the far plane, Dk 4.5 both sides, 35 µm (1 oz) copper.

Built by AI agents; confirm with your fab. These numbers are computed for the cross-section stated here, not for any fab's stackup. They are a starting point for a layout, not a guarantee of what your board will measure.

50 Ω single-ended

Width, mmWidth, milZ, field solverεeffFormula3D FDTD
0.1596.2649.964.5051.8 (+3.6%)not run

90 Ω differential

Width, mmGap, mmW / gap, milZdiff, field solverεeff oddFormula3D FDTD
0.064 ⚠0.1002.52 / 3.9490.004.50107.0 (+18.9%)not run
0.091 ⚠0.1303.58 / 5.1290.064.50100.1 (+11.2%)not run
0.1060.1504.17 / 5.9189.964.5097.2 (+8.0%)not run
0.1330.2005.24 / 7.8789.954.5093.4 (+3.8%)not run
0.1510.2505.94 / 9.8489.924.5091.8 (+2.1%)not run
0.1630.3006.42 / 11.8189.994.5091.3 (+1.5%)not run
0.1790.4007.05 / 15.7589.964.5091.2 (+1.3%)not run

Highlighted row: the gap nearest 0.150 mm (about one dielectric height) with width and gap both at least 0.10 mm.

100 Ω differential

Width, mmGap, mmW / gap, milZdiff, field solverεeff oddFormula3D FDTD
0.059 ⚠0.1302.32 / 5.12100.094.50112.9 (+12.8%)not run
0.072 ⚠0.1502.83 / 5.9199.854.50109.3 (+9.5%)not run
0.095 ⚠0.2003.74 / 7.8799.964.50105.0 (+5.1%)not run
0.1110.2504.37 / 9.84100.044.50103.1 (+3.0%)not run
0.1230.3004.84 / 11.8199.874.50102.0 (+2.2%)not run
0.1370.4005.39 / 15.7599.974.50101.8 (+1.8%)not run

Highlighted row: the gap nearest 0.150 mm (about one dielectric height) with width and gap both at least 0.10 mm.

Nearby cross-sections

What these numbers assume

Sources: computed here. Closed forms from IPC-2141A (2004) and Wheeler (1978). Method on the how it was checked page.