PCB Impedance Tables

50, 90 and 100 Ω trace width: stripline, 0.15 mm and 0.40 mm dielectric, Dk 4.5, 35 µm copper

Inner-layer trace between two solid planes: h1 = 0.15 mm below it, h2 = 0.40 mm from the trace base to the far plane, Dk 4.5 both sides, 35 µm (1 oz) copper.

Built by AI agents; confirm with your fab. These numbers are computed for the cross-section stated here, not for any fab's stackup. They are a starting point for a layout, not a guarantee of what your board will measure.

50 Ω single-ended

Width, mmWidth, milZ, field solverεeffFormula3D FDTD
0.1445.6749.964.5050.6 (+1.3%)not run

90 Ω differential

Width, mmGap, mmW / gap, milZdiff, field solverεeff oddFormula3D FDTD
0.063 ⚠0.1002.48 / 3.9490.044.50105.8 (+17.5%)not run
0.089 ⚠0.1303.50 / 5.1290.134.5099.4 (+10.3%)not run
0.1030.1504.06 / 5.9190.104.5096.7 (+7.3%)not run
0.1290.2005.08 / 7.8789.914.5093.0 (+3.4%)not run
0.1450.2505.71 / 9.8489.944.5091.6 (+1.8%)not run
0.1560.3006.14 / 11.8189.934.5091.0 (+1.1%)not run
0.1690.4006.65 / 15.7589.974.5090.6 (+0.7%)not run

Highlighted row: the gap nearest 0.150 mm (about one dielectric height) with width and gap both at least 0.10 mm.

100 Ω differential

Width, mmGap, mmW / gap, milZdiff, field solverεeff oddFormula3D FDTD
0.058 ⚠0.1302.28 / 5.12100.104.50112.1 (+12.0%)not run
0.070 ⚠0.1502.76 / 5.91100.014.50109.0 (+8.9%)not run
0.092 ⚠0.2003.62 / 7.87100.044.50104.8 (+4.7%)not run
0.1070.2504.21 / 9.84100.044.50102.8 (+2.7%)not run
0.1180.3004.65 / 11.8199.864.50101.6 (+1.7%)not run
0.1290.4005.08 / 15.75100.144.50101.3 (+1.2%)not run

Highlighted row: the gap nearest 0.150 mm (about one dielectric height) with width and gap both at least 0.10 mm.

Nearby cross-sections

What these numbers assume

Sources: computed here. Closed forms from IPC-2141A (2004) and Wheeler (1978). Method on the how it was checked page.