PCB Impedance Tables

50, 90 and 100 Ω trace width: stripline, 0.20 mm and 0.50 mm dielectric, Dk 4.5, 35 µm copper

Inner-layer trace between two solid planes: h1 = 0.20 mm below it, h2 = 0.50 mm from the trace base to the far plane, Dk 4.5 both sides, 35 µm (1 oz) copper.

Built by AI agents; confirm with your fab. These numbers are computed for the cross-section stated here, not for any fab's stackup. They are a starting point for a layout, not a guarantee of what your board will measure.

50 Ω single-ended

Width, mmWidth, milZ, field solverεeffFormula3D FDTD
0.2017.9149.984.5050.6 (+1.2%)not run

90 Ω differential

Width, mmGap, mmW / gap, milZdiff, field solverεeff oddFormula3D FDTD
0.071 ⚠0.1002.80 / 3.9489.864.50110.3 (+22.8%)not run
0.1040.1304.09 / 5.1289.924.50102.7 (+14.2%)not run
0.1220.1504.80 / 5.9189.974.5099.5 (+10.6%)not run
0.1580.2006.22 / 7.8789.924.5094.6 (+5.2%)not run
0.1820.2507.17 / 9.8489.944.5092.4 (+2.8%)not run
0.1990.3007.83 / 11.8190.074.5091.4 (+1.5%)not run
0.2210.4008.70 / 15.7589.984.5090.6 (+0.6%)not run

Highlighted row: the gap nearest 0.200 mm (about one dielectric height) with width and gap both at least 0.10 mm.

100 Ω differential

Width, mmGap, mmW / gap, milZdiff, field solverεeff oddFormula3D FDTD
0.041 ⚠0.1001.61 / 3.94100.024.50124.3 (+24.3%)not run
0.067 ⚠0.1302.64 / 5.1299.884.50115.8 (+16.0%)not run
0.082 ⚠0.1503.23 / 5.9199.894.50112.2 (+12.3%)not run
0.1120.2004.41 / 7.8799.974.50106.7 (+6.7%)not run
0.1340.2505.28 / 9.8499.924.50103.8 (+3.9%)not run
0.1500.3005.91 / 11.8199.944.50102.3 (+2.4%)not run
0.1700.4006.69 / 15.7599.984.50101.2 (+1.2%)not run

Highlighted row: the gap nearest 0.200 mm (about one dielectric height) with width and gap both at least 0.10 mm.

Nearby cross-sections

What these numbers assume

Sources: computed here. Closed forms from IPC-2141A (2004) and Wheeler (1978). Method on the how it was checked page.