PCB Impedance Tables

50, 90 and 100 Ω trace width: stripline, 0.50 mm and 0.60 mm dielectric, Dk 4.0, 18 µm copper

Inner-layer trace between two solid planes: h1 = 0.50 mm below it, h2 = 0.60 mm from the trace base to the far plane, Dk 4.0 both sides, 18 µm (½ oz) copper.

Built by AI agents; confirm with your fab. These numbers are computed for the cross-section stated here, not for any fab's stackup. They are a starting point for a layout, not a guarantee of what your board will measure.

50 Ω single-ended

Width, mmWidth, milZ, field solverεeffFormula3D FDTD
0.51720.3549.984.0049.6 (-0.7%)not run

90 Ω differential

Width, mmGap, mmW / gap, milZdiff, field solverεeff oddFormula3D FDTD
0.1670.1006.57 / 3.9490.024.00115.9 (+28.7%)not run
0.2250.1308.86 / 5.1290.044.00107.6 (+19.5%)not run
0.2600.15010.24 / 5.9189.964.00103.6 (+15.2%)not run
0.3310.20013.03 / 7.8789.994.0097.4 (+8.3%)not run
0.3860.25015.20 / 9.8489.964.0093.9 (+4.4%)not run
0.4280.30016.85 / 11.8189.974.0091.9 (+2.1%)not run
0.4880.40019.21 / 15.7590.034.0089.8 (-0.2%)not run

Highlighted row: the gap nearest 0.300 mm (about one dielectric height) with width and gap both at least 0.10 mm.

100 Ω differential

Width, mmGap, mmW / gap, milZdiff, field solverεeff oddFormula3D FDTD
0.1100.1004.33 / 3.94100.074.00131.0 (+30.9%)not run
0.1550.1306.10 / 5.1299.924.00121.9 (+22.0%)not run
0.1820.1507.17 / 5.9199.964.00117.7 (+17.8%)not run
0.2410.2009.49 / 7.8799.994.00110.6 (+10.7%)not run
0.2890.25011.38 / 9.8499.954.00106.4 (+6.4%)not run
0.3260.30012.83 / 11.81100.054.00103.9 (+3.9%)not run
0.3830.40015.08 / 15.7599.994.00101.0 (+1.0%)not run

Highlighted row: the gap nearest 0.300 mm (about one dielectric height) with width and gap both at least 0.10 mm.

Nearby cross-sections

What these numbers assume