PCB Impedance Tables

50, 90 and 100 Ω trace width: stripline, 0.50 mm and 0.60 mm dielectric, Dk 4.0, 35 µm copper

Inner-layer trace between two solid planes: h1 = 0.50 mm below it, h2 = 0.60 mm from the trace base to the far plane, Dk 4.0 both sides, 35 µm (1 oz) copper.

Built by AI agents; confirm with your fab. These numbers are computed for the cross-section stated here, not for any fab's stackup. They are a starting point for a layout, not a guarantee of what your board will measure.

50 Ω single-ended

Width, mmWidth, milZ, field solverεeffFormula3D FDTD
0.48619.1350.024.0049.6 (-0.8%)not run

90 Ω differential

Width, mmGap, mmW / gap, milZdiff, field solverεeff oddFormula3D FDTD
0.1090.1004.29 / 3.9490.084.00124.4 (+38.1%)not run
0.1670.1306.57 / 5.1290.004.00113.7 (+26.3%)not run
0.2020.1507.95 / 5.9190.014.00108.8 (+20.9%)not run
0.2770.20010.91 / 7.8790.004.00100.9 (+12.1%)not run
0.3360.25013.23 / 9.8489.994.0096.3 (+7.1%)not run
0.3810.30015.00 / 11.8190.024.0093.7 (+4.1%)not run
0.4470.40017.60 / 15.7590.014.0090.8 (+0.9%)not run

Highlighted row: the gap nearest 0.300 mm (about one dielectric height) with width and gap both at least 0.10 mm.

100 Ω differential

Width, mmGap, mmW / gap, milZdiff, field solverεeff oddFormula3D FDTD
0.065 ⚠0.1002.56 / 3.9499.924.00139.4 (+39.5%)not run
0.1060.1304.17 / 5.12100.004.00128.7 (+28.7%)not run
0.1330.1505.24 / 5.9199.954.00123.4 (+23.5%)not run
0.1930.2007.60 / 7.87100.004.00114.6 (+14.6%)not run
0.2430.2509.57 / 9.84100.034.00109.3 (+9.3%)not run
0.2830.30011.14 / 11.81100.044.00106.0 (+6.0%)not run
0.3430.40013.50 / 15.7599.964.00102.3 (+2.4%)not run

Highlighted row: the gap nearest 0.300 mm (about one dielectric height) with width and gap both at least 0.10 mm.

Nearby cross-sections

What these numbers assume