PCB Impedance Tables

50, 90 and 100 Ω trace width: stripline, 0.40 mm and 0.60 mm dielectric, Dk 4.0, 18 µm copper

Inner-layer trace between two solid planes: h1 = 0.40 mm below it, h2 = 0.60 mm from the trace base to the far plane, Dk 4.0 both sides, 18 µm (½ oz) copper.

Built by AI agents; confirm with your fab. These numbers are computed for the cross-section stated here, not for any fab's stackup. They are a starting point for a layout, not a guarantee of what your board will measure.

50 Ω single-ended

Width, mmWidth, milZ, field solverεeffFormula3D FDTD
0.44917.6850.034.0049.8 (-0.4%)not run

90 Ω differential

Width, mmGap, mmW / gap, milZdiff, field solverεeff oddFormula3D FDTD
0.1630.1006.42 / 3.9489.934.00112.6 (+25.2%)not run
0.2170.1308.54 / 5.1289.954.00104.8 (+16.5%)not run
0.2470.1509.72 / 5.9190.014.00101.4 (+12.7%)not run
0.3100.20012.20 / 7.8790.054.0095.8 (+6.4%)not run
0.3570.25014.06 / 9.8489.984.0092.8 (+3.1%)not run
0.3930.30015.47 / 11.8190.054.0091.1 (+1.1%)not run
0.4420.40017.40 / 15.7589.994.0089.6 (-0.5%)not run

Highlighted row: the gap nearest 0.300 mm (about one dielectric height) with width and gap both at least 0.10 mm.

100 Ω differential

Width, mmGap, mmW / gap, milZdiff, field solverεeff oddFormula3D FDTD
0.1080.1004.25 / 3.94100.054.00127.7 (+27.6%)not run
0.1500.1305.91 / 5.12100.024.00119.1 (+19.1%)not run
0.1750.1506.89 / 5.9199.994.00115.2 (+15.2%)not run
0.2290.2009.02 / 7.8799.954.00108.5 (+8.6%)not run
0.2700.25010.63 / 9.8499.974.00104.9 (+5.0%)not run
0.3030.30011.93 / 11.81100.044.00102.7 (+2.6%)not run
0.3480.40013.70 / 15.75100.024.00100.6 (+0.6%)not run

Highlighted row: the gap nearest 0.300 mm (about one dielectric height) with width and gap both at least 0.10 mm.

Nearby cross-sections

What these numbers assume

Sources: computed here. Closed forms from IPC-2141A (2004) and Wheeler (1978). Method on the how it was checked page.