PCB Impedance Tables

50, 90 and 100 Ω trace width: stripline, 0.50 mm and 0.60 mm dielectric, Dk 3.5, 18 µm copper

Inner-layer trace between two solid planes: h1 = 0.50 mm below it, h2 = 0.60 mm from the trace base to the far plane, Dk 3.5 both sides, 18 µm (½ oz) copper.

Built by AI agents; confirm with your fab. These numbers are computed for the cross-section stated here, not for any fab's stackup. They are a starting point for a layout, not a guarantee of what your board will measure.

50 Ω single-ended

Width, mmWidth, milZ, field solverεeffFormula3D FDTD
0.58523.0350.013.5049.6 (-0.7%)not run

90 Ω differential

Width, mmGap, mmW / gap, milZdiff, field solverεeff oddFormula3D FDTD
0.2150.1008.46 / 3.9489.993.50113.7 (+26.4%)not run
0.2820.13011.10 / 5.1290.043.50105.5 (+17.2%)not run
0.3210.15012.64 / 5.9189.993.50101.7 (+13.0%)not run
0.3990.20015.71 / 7.8789.983.5095.8 (+6.5%)not run
0.4560.25017.95 / 9.8490.043.5092.7 (+3.0%)not run
0.5000.30019.69 / 11.8190.043.5090.9 (+1.0%)not run
0.5630.40022.17 / 15.7590.013.5089.1 (-1.0%)not run

Highlighted row: the gap nearest 0.300 mm (about one dielectric height) with width and gap both at least 0.10 mm.

100 Ω differential

Width, mmGap, mmW / gap, milZdiff, field solverεeff oddFormula3D FDTD
0.1440.1005.67 / 3.94100.003.50129.7 (+29.7%)not run
0.1970.1307.76 / 5.1299.993.50120.5 (+20.5%)not run
0.2290.1509.02 / 5.9199.953.50116.2 (+16.2%)not run
0.2960.20011.65 / 7.8799.963.50109.1 (+9.2%)not run
0.3480.25013.70 / 9.84100.003.50105.2 (+5.2%)not run
0.3890.30015.31 / 11.8199.973.50102.7 (+2.8%)not run
0.4480.40017.64 / 15.7599.983.50100.2 (+0.3%)not run

Highlighted row: the gap nearest 0.300 mm (about one dielectric height) with width and gap both at least 0.10 mm.

Nearby cross-sections

What these numbers assume

Sources: computed here. Closed forms from IPC-2141A (2004) and Wheeler (1978). Method on the how it was checked page.