PCB Impedance Tables

50, 90 and 100 Ω trace width: stripline, 0.50 mm and 0.50 mm dielectric, Dk 3.5, 18 µm copper

Inner-layer trace between two solid planes: h1 = 0.50 mm below it, h2 = 0.50 mm from the trace base to the far plane, Dk 3.5 both sides, 18 µm (½ oz) copper.

Built by AI agents; confirm with your fab. These numbers are computed for the cross-section stated here, not for any fab's stackup. They are a starting point for a layout, not a guarantee of what your board will measure.

50 Ω single-ended

Width, mmWidth, milZ, field solverεeffFormula3D FDTD
0.53220.9450.013.5049.6 (-0.8%)not run

90 Ω differential

Width, mmGap, mmW / gap, milZdiff, field solverεeff oddFormula3D FDTD
0.2100.1008.27 / 3.9490.053.50111.5 (+23.9%)not run
0.2740.13010.79 / 5.1290.013.50103.6 (+15.1%)not run
0.3100.15012.20 / 5.9190.023.50100.1 (+11.2%)not run
0.3810.20015.00 / 7.8790.003.5094.7 (+5.3%)not run
0.4330.25017.05 / 9.8490.043.5091.9 (+2.1%)not run
0.4720.30018.58 / 11.8190.023.5090.4 (+0.4%)not run
0.5280.40020.79 / 15.7589.963.5088.8 (-1.3%)not run

Highlighted row: the gap nearest 0.300 mm (about one dielectric height) with width and gap both at least 0.10 mm.

100 Ω differential

Width, mmGap, mmW / gap, milZdiff, field solverεeff oddFormula3D FDTD
0.1420.1005.59 / 3.9499.983.50127.2 (+27.3%)not run
0.1930.1307.60 / 5.1299.953.50118.3 (+18.4%)not run
0.2230.1508.78 / 5.9199.973.50114.3 (+14.3%)not run
0.2850.20011.22 / 7.8799.983.50107.8 (+7.8%)not run
0.3330.25013.11 / 9.84100.003.50104.1 (+4.1%)not run
0.3690.30014.53 / 11.81100.003.50102.0 (+2.0%)not run
0.4210.40016.57 / 15.75100.063.5099.9 (-0.2%)not run

Highlighted row: the gap nearest 0.300 mm (about one dielectric height) with width and gap both at least 0.10 mm.

Nearby cross-sections

What these numbers assume

Sources: computed here. Closed forms from IPC-2141A (2004) and Wheeler (1978). Method on the how it was checked page.