PCB Impedance Tables

50, 90 and 100 Ω trace width: stripline, 0.60 mm and 0.60 mm dielectric, Dk 3.5, 18 µm copper

Inner-layer trace between two solid planes: h1 = 0.60 mm below it, h2 = 0.60 mm from the trace base to the far plane, Dk 3.5 both sides, 18 µm (½ oz) copper.

Built by AI agents; confirm with your fab. These numbers are computed for the cross-section stated here, not for any fab's stackup. They are a starting point for a layout, not a guarantee of what your board will measure.

50 Ω single-ended

Width, mmWidth, milZ, field solverεeffFormula3D FDTD
0.64625.4349.993.5049.6 (-0.7%)not run

90 Ω differential

Width, mmGap, mmW / gap, milZdiff, field solverεeff oddFormula3D FDTD
0.2190.1008.62 / 3.9490.053.50116.3 (+29.1%)not run
0.2910.13011.46 / 5.1290.003.50107.5 (+19.4%)not run
0.3320.15013.07 / 5.9190.033.50103.5 (+15.0%)not run
0.4180.20016.46 / 7.8790.003.5097.1 (+7.8%)not run
0.4810.25018.94 / 9.8490.033.5093.7 (+4.0%)not run
0.5310.30020.91 / 11.8190.053.5091.6 (+1.7%)not run
0.6030.40023.74 / 15.7589.973.5089.4 (-0.6%)not run

Highlighted row: the gap nearest 0.300 mm (about one dielectric height) with width and gap both at least 0.10 mm.

100 Ω differential

Width, mmGap, mmW / gap, milZdiff, field solverεeff oddFormula3D FDTD
0.1460.1005.75 / 3.94100.003.50132.4 (+32.4%)not run
0.2010.1307.91 / 5.12100.033.50122.9 (+22.8%)not run
0.2350.1509.25 / 5.9199.953.50118.3 (+18.3%)not run
0.3070.20012.09 / 7.87100.023.50110.8 (+10.7%)not run
0.3640.25014.33 / 9.8499.983.50106.4 (+6.4%)not run
0.4100.30016.14 / 11.81100.023.50103.6 (+3.6%)not run
0.4770.40018.78 / 15.7599.973.50100.7 (+0.8%)not run

Highlighted row: the gap nearest 0.300 mm (about one dielectric height) with width and gap both at least 0.10 mm.

Nearby cross-sections

What these numbers assume

Sources: computed here. Closed forms from IPC-2141A (2004) and Wheeler (1978). Method on the how it was checked page.