PCB Impedance Tables

50, 90 and 100 Ω trace width: stripline, 0.40 mm and 0.50 mm dielectric, Dk 3.5, 18 µm copper

Inner-layer trace between two solid planes: h1 = 0.40 mm below it, h2 = 0.50 mm from the trace base to the far plane, Dk 3.5 both sides, 18 µm (½ oz) copper.

Built by AI agents; confirm with your fab. These numbers are computed for the cross-section stated here, not for any fab's stackup. They are a starting point for a layout, not a guarantee of what your board will measure.

50 Ω single-ended

Width, mmWidth, milZ, field solverεeffFormula3D FDTD
0.47118.5449.993.5049.6 (-0.7%)not run

90 Ω differential

Width, mmGap, mmW / gap, milZdiff, field solverεeff oddFormula3D FDTD
0.2040.1008.03 / 3.9489.963.50108.7 (+20.8%)not run
0.2620.13010.31 / 5.1290.033.50101.4 (+12.7%)not run
0.2940.15011.57 / 5.9190.023.5098.3 (+9.2%)not run
0.3570.20014.06 / 7.8790.033.5093.5 (+3.9%)not run
0.4020.25015.83 / 9.8490.023.5091.1 (+1.2%)not run
0.4360.30017.17 / 11.8190.033.5089.8 (-0.3%)not run
0.4810.40018.94 / 15.7590.023.5088.7 (-1.4%)not run

Highlighted row: the gap nearest 0.300 mm (about one dielectric height) with width and gap both at least 0.10 mm.

100 Ω differential

Width, mmGap, mmW / gap, milZdiff, field solverεeff oddFormula3D FDTD
0.1390.1005.47 / 3.9499.963.50124.2 (+24.2%)not run
0.1870.1307.36 / 5.1299.923.50115.7 (+15.8%)not run
0.2140.1508.43 / 5.9199.973.50112.1 (+12.1%)not run
0.2700.20010.63 / 7.87100.013.50106.1 (+6.1%)not run
0.3110.25012.24 / 9.84100.053.50103.0 (+3.0%)not run
0.3430.30013.50 / 11.81100.053.50101.2 (+1.1%)not run
0.3860.40015.20 / 15.75100.043.5099.5 (-0.5%)not run

Highlighted row: the gap nearest 0.300 mm (about one dielectric height) with width and gap both at least 0.10 mm.

Nearby cross-sections

What these numbers assume

Sources: computed here. Closed forms from IPC-2141A (2004) and Wheeler (1978). Method on the how it was checked page.