PCB Impedance Tables

50, 90 and 100 Ω trace width: stripline, 0.30 mm and 0.50 mm dielectric, Dk 3.5, 18 µm copper

Inner-layer trace between two solid planes: h1 = 0.30 mm below it, h2 = 0.50 mm from the trace base to the far plane, Dk 3.5 both sides, 18 µm (½ oz) copper.

Built by AI agents; confirm with your fab. These numbers are computed for the cross-section stated here, not for any fab's stackup. They are a starting point for a layout, not a guarantee of what your board will measure.

50 Ω single-ended

Width, mmWidth, milZ, field solverεeffFormula3D FDTD
0.39115.3949.993.5049.9 (-0.2%)not run

90 Ω differential

Width, mmGap, mmW / gap, milZdiff, field solverεeff oddFormula3D FDTD
0.1910.1007.52 / 3.9490.063.50105.3 (+16.9%)not run
0.2410.1309.49 / 5.1290.023.5098.8 (+9.8%)not run
0.2680.15010.55 / 5.9190.043.5096.1 (+6.7%)not run
0.3190.20012.56 / 7.8790.033.5092.2 (+2.4%)not run
0.3550.25013.98 / 9.8490.023.5090.3 (+0.3%)not run
0.3810.30015.00 / 11.8189.983.5089.4 (-0.7%)not run
0.4150.40016.34 / 15.7589.963.5088.8 (-1.3%)not run

Highlighted row: the gap nearest 0.300 mm (about one dielectric height) with width and gap both at least 0.10 mm.

100 Ω differential

Width, mmGap, mmW / gap, milZdiff, field solverεeff oddFormula3D FDTD
0.1330.1005.24 / 3.9499.953.50120.0 (+20.1%)not run
0.1750.1306.89 / 5.1299.933.50112.5 (+12.5%)not run
0.1980.1507.80 / 5.91100.073.50109.3 (+9.2%)not run
0.2440.2009.61 / 7.87100.063.50104.4 (+4.3%)not run
0.2780.25010.94 / 9.8499.973.50101.7 (+1.8%)not run
0.3020.30011.89 / 11.81100.023.50100.5 (+0.5%)not run
0.3350.40013.19 / 15.7599.953.5099.3 (-0.6%)not run

Highlighted row: the gap nearest 0.300 mm (about one dielectric height) with width and gap both at least 0.10 mm.

Nearby cross-sections

What these numbers assume

Sources: computed here. Closed forms from IPC-2141A (2004) and Wheeler (1978). Method on the how it was checked page.