PCB Impedance Tables

50, 90 and 100 Ω trace width: stripline, 0.30 mm and 0.60 mm dielectric, Dk 3.5, 18 µm copper

Inner-layer trace between two solid planes: h1 = 0.30 mm below it, h2 = 0.60 mm from the trace base to the far plane, Dk 3.5 both sides, 18 µm (½ oz) copper.

Built by AI agents; confirm with your fab. These numbers are computed for the cross-section stated here, not for any fab's stackup. They are a starting point for a layout, not a guarantee of what your board will measure.

50 Ω single-ended

Width, mmWidth, milZ, field solverεeffFormula3D FDTD
0.41616.3850.043.5050.2 (+0.4%)not run

90 Ω differential

Width, mmGap, mmW / gap, milZdiff, field solverεeff oddFormula3D FDTD
0.1940.1007.64 / 3.9490.023.50106.7 (+18.5%)not run
0.2460.1309.69 / 5.1289.983.5099.8 (+11.0%)not run
0.2740.15010.79 / 5.9190.013.5097.0 (+7.8%)not run
0.3280.20012.91 / 7.8790.043.5092.8 (+3.1%)not run
0.3670.25014.45 / 9.8489.973.5090.7 (+0.8%)not run
0.3950.30015.55 / 11.8190.013.5089.6 (-0.4%)not run
0.4330.40017.05 / 15.7589.973.5088.9 (-1.2%)not run

Highlighted row: the gap nearest 0.300 mm (about one dielectric height) with width and gap both at least 0.10 mm.

100 Ω differential

Width, mmGap, mmW / gap, milZdiff, field solverεeff oddFormula3D FDTD
0.1340.1005.28 / 3.94100.033.50121.7 (+21.6%)not run
0.1770.1306.97 / 5.12100.033.50113.8 (+13.8%)not run
0.2020.1507.95 / 5.9199.963.50110.3 (+10.3%)not run
0.2500.2009.84 / 7.87100.053.50105.1 (+5.0%)not run
0.2860.25011.26 / 9.8499.953.50102.3 (+2.3%)not run
0.3120.30012.28 / 11.81100.043.50100.9 (+0.8%)not run
0.3480.40013.70 / 15.75100.023.5099.7 (-0.4%)not run

Highlighted row: the gap nearest 0.300 mm (about one dielectric height) with width and gap both at least 0.10 mm.

Nearby cross-sections

What these numbers assume

Sources: computed here. Closed forms from IPC-2141A (2004) and Wheeler (1978). Method on the how it was checked page.