PCB Impedance Tables

50, 90 and 100 Ω trace width: stripline, 0.20 mm and 0.60 mm dielectric, Dk 3.5, 18 µm copper

Inner-layer trace between two solid planes: h1 = 0.20 mm below it, h2 = 0.60 mm from the trace base to the far plane, Dk 3.5 both sides, 18 µm (½ oz) copper.

Built by AI agents; confirm with your fab. These numbers are computed for the cross-section stated here, not for any fab's stackup. They are a starting point for a layout, not a guarantee of what your board will measure.

50 Ω single-ended

Width, mmWidth, milZ, field solverεeffFormula3D FDTD
0.29911.7750.023.5051.1 (+2.2%)not run

90 Ω differential

Width, mmGap, mmW / gap, milZdiff, field solverεeff oddFormula3D FDTD
0.1680.1006.61 / 3.9490.083.50101.4 (+12.6%)not run
0.2060.1308.11 / 5.1290.013.5096.0 (+6.6%)not run
0.2260.1508.90 / 5.9190.013.5093.8 (+4.2%)not run
0.2620.20010.31 / 7.8790.063.5091.0 (+1.0%)not run
0.2870.25011.30 / 9.8489.943.5089.8 (-0.2%)not run
0.3040.30011.97 / 11.8190.063.5089.5 (-0.7%)not run
0.3270.40012.87 / 15.7589.933.5089.5 (-0.5%)not run

Highlighted row: the gap nearest 0.200 mm (about one dielectric height) with width and gap both at least 0.10 mm.

100 Ω differential

Width, mmGap, mmW / gap, milZdiff, field solverεeff oddFormula3D FDTD
0.1200.1004.72 / 3.9499.983.50115.2 (+15.2%)not run
0.1530.1306.02 / 5.1299.923.50108.7 (+8.8%)not run
0.1710.1506.73 / 5.9199.903.50106.0 (+6.1%)not run
0.2040.2008.03 / 7.8799.943.50102.4 (+2.5%)not run
0.2260.2508.90 / 9.84100.053.50101.0 (+0.9%)not run
0.2430.3009.57 / 11.81100.013.50100.2 (+0.2%)not run
0.2640.40010.39 / 15.7599.993.50100.1 (+0.1%)not run

Highlighted row: the gap nearest 0.200 mm (about one dielectric height) with width and gap both at least 0.10 mm.

Nearby cross-sections

What these numbers assume

Sources: computed here. Closed forms from IPC-2141A (2004) and Wheeler (1978). Method on the how it was checked page.