50, 90 and 100 Ω trace width: stripline, 0.25 mm and 0.50 mm dielectric, Dk 4.5, 35 µm copper

Inner-layer trace between two solid planes: h1 = 0.25 mm below it, h2 = 0.50 mm from the trace base to the far plane, Dk 4.5 both sides, 35 µm (1 oz) copper.

Built by AI agents; confirm with your fab. These numbers are computed for the cross-section stated here, not for any fab's stackup. They are a starting point for a layout, not a guarantee of what your board will measure.

50 Ω single-ended

Width, mmWidth, milZ, field solverεeffFormula3D FDTD
0.2439.5750.004.5050.1 (+0.3%)not run

90 Ω differential

Width, mmGap, mmW / gap, milZdiff, field solverεeff oddFormula3D FDTD
0.075 ⚠0.1002.95 / 3.9489.884.50113.6 (+26.3%)not run
0.1120.1304.41 / 5.1290.014.50105.3 (+17.0%)not run
0.1340.1505.28 / 5.9189.914.50101.5 (+12.9%)not run
0.1760.2006.93 / 7.8790.034.5096.1 (+6.7%)not run
0.2070.2508.15 / 9.8489.984.5093.2 (+3.5%)not run
0.2290.3009.02 / 11.8190.044.5091.7 (+1.9%)not run
0.2590.40010.20 / 15.7589.964.5090.2 (+0.3%)not run

Highlighted row: the gap nearest 0.250 mm (about one dielectric height) with width and gap both at least 0.10 mm.

100 Ω differential

Width, mmGap, mmW / gap, milZdiff, field solverεeff oddFormula3D FDTD
0.043 ⚠0.1001.69 / 3.94100.014.50127.7 (+27.7%)not run
0.071 ⚠0.1302.80 / 5.12100.064.50119.0 (+18.9%)not run
0.088 ⚠0.1503.46 / 5.91100.124.50114.9 (+14.8%)not run
0.1250.2004.92 / 7.8799.904.50108.2 (+8.3%)not run
0.1510.2505.94 / 9.84100.084.50105.0 (+4.9%)not run
0.1710.3006.73 / 11.81100.094.50103.1 (+3.0%)not run
0.1990.4007.83 / 15.7599.914.50101.0 (+1.1%)not run

Highlighted row: the gap nearest 0.250 mm (about one dielectric height) with width and gap both at least 0.10 mm.

Nearby cross-sections

What these numbers assume

Sources: computed here. Closed forms from IPC-2141A (2004) and Wheeler (1978). Method on the how it was checked page.