PCB Impedance Tables

50, 90 and 100 Ω trace width: stripline, 0.10 mm and 0.50 mm dielectric, Dk 4.0, 18 µm copper

Inner-layer trace between two solid planes: h1 = 0.10 mm below it, h2 = 0.50 mm from the trace base to the far plane, Dk 4.0 both sides, 18 µm (½ oz) copper.

Built by AI agents; confirm with your fab. These numbers are computed for the cross-section stated here, not for any fab's stackup. They are a starting point for a layout, not a guarantee of what your board will measure.

50 Ω single-ended

Width, mmWidth, milZ, field solverεeffFormula3D FDTD
0.1315.1650.014.0052.6 (+5.2%)not run

90 Ω differential

Width, mmGap, mmW / gap, milZdiff, field solverεeff oddFormula3D FDTD
0.096 ⚠0.1003.78 / 3.9489.914.0094.7 (+5.3%)not run
0.1120.1304.41 / 5.1290.104.0092.0 (+2.1%)not run
0.1210.1504.76 / 5.9189.864.0090.8 (+1.0%)not run
0.1340.2005.28 / 7.8790.074.0090.4 (+0.3%)not run
0.1430.2505.63 / 9.8489.974.0090.5 (+0.5%)not run
0.1490.3005.87 / 11.8189.874.0090.8 (+1.1%)not run
0.1550.4006.10 / 15.7590.084.0092.1 (+2.2%)not run

Highlighted row: the gap nearest 0.130 mm (about one dielectric height) with width and gap both at least 0.10 mm.

100 Ω differential

Width, mmGap, mmW / gap, milZdiff, field solverεeff oddFormula3D FDTD
0.069 ⚠0.1002.72 / 3.94100.194.00107.0 (+6.8%)not run
0.084 ⚠0.1303.31 / 5.12100.184.00103.4 (+3.2%)not run
0.092 ⚠0.1503.62 / 5.9199.854.00101.9 (+2.1%)not run
0.1040.2004.09 / 7.87100.144.00101.2 (+1.0%)not run
0.1120.2504.41 / 9.84100.124.00101.2 (+1.1%)not run
0.1180.3004.65 / 11.8199.834.00101.4 (+1.5%)not run
0.1240.4004.88 / 15.7599.914.00102.5 (+2.6%)not run

Highlighted row: the gap nearest 0.130 mm (about one dielectric height) with width and gap both at least 0.10 mm.

Nearby cross-sections

What these numbers assume

Sources: computed here. Closed forms from IPC-2141A (2004) and Wheeler (1978). Method on the how it was checked page.