PCB Impedance Tables

50, 90 and 100 Ω trace width: stripline, 0.10 mm and 0.40 mm dielectric, Dk 3.5, 18 µm copper

Inner-layer trace between two solid planes: h1 = 0.10 mm below it, h2 = 0.40 mm from the trace base to the far plane, Dk 3.5 both sides, 18 µm (½ oz) copper.

Built by AI agents; confirm with your fab. These numbers are computed for the cross-section stated here, not for any fab's stackup. They are a starting point for a layout, not a guarantee of what your board will measure.

50 Ω single-ended

Width, mmWidth, milZ, field solverεeffFormula3D FDTD
0.1465.7550.073.5051.9 (+3.6%)not run

90 Ω differential

Width, mmGap, mmW / gap, milZdiff, field solverεeff oddFormula3D FDTD
0.1140.1004.49 / 3.9490.103.5093.8 (+4.2%)not run
0.1310.1305.16 / 5.1290.133.5091.5 (+1.5%)not run
0.1400.1505.51 / 5.9189.963.5090.5 (+0.6%)not run
0.1540.2006.06 / 7.8789.903.5090.0 (+0.1%)not run
0.1620.2506.38 / 9.8490.063.5090.4 (+0.4%)not run
0.1680.3006.61 / 11.8189.913.5090.7 (+0.9%)not run
0.1740.4006.85 / 15.7589.983.5091.6 (+1.8%)not run

Highlighted row: the gap nearest 0.130 mm (about one dielectric height) with width and gap both at least 0.10 mm.

100 Ω differential

Width, mmGap, mmW / gap, milZdiff, field solverεeff oddFormula3D FDTD
0.085 ⚠0.1003.35 / 3.9499.993.50105.9 (+5.9%)not run
0.1010.1303.98 / 5.1299.953.50102.7 (+2.7%)not run
0.1090.1504.29 / 5.9199.873.50101.5 (+1.6%)not run
0.1210.2004.76 / 7.87100.173.50101.1 (+0.9%)not run
0.1300.2505.12 / 9.8499.843.50100.8 (+1.0%)not run
0.1350.3005.31 / 11.8199.883.50101.2 (+1.3%)not run
0.1410.4005.55 / 15.7599.843.50101.9 (+2.1%)not run

Highlighted row: the gap nearest 0.130 mm (about one dielectric height) with width and gap both at least 0.10 mm.

Nearby cross-sections

What these numbers assume

Sources: computed here. Closed forms from IPC-2141A (2004) and Wheeler (1978). Method on the how it was checked page.