PCB Impedance Tables

50, 90 and 100 Ω trace width: stripline, 0.10 mm and 0.60 mm dielectric, Dk 4.0, 18 µm copper

Inner-layer trace between two solid planes: h1 = 0.10 mm below it, h2 = 0.60 mm from the trace base to the far plane, Dk 4.0 both sides, 18 µm (½ oz) copper.

Built by AI agents; confirm with your fab. These numbers are computed for the cross-section stated here, not for any fab's stackup. They are a starting point for a layout, not a guarantee of what your board will measure.

50 Ω single-ended

Width, mmWidth, milZ, field solverεeffFormula3D FDTD
0.1345.2849.924.0053.1 (+6.4%)not run

90 Ω differential

Width, mmGap, mmW / gap, milZdiff, field solverεeff oddFormula3D FDTD
0.096 ⚠0.1003.78 / 3.9489.984.0094.7 (+5.2%)not run
0.1130.1304.45 / 5.1289.904.0091.5 (+1.8%)not run
0.1210.1504.76 / 5.9190.004.0090.6 (+0.7%)not run
0.1350.2005.31 / 7.8789.974.0089.8 (-0.1%)not run
0.1440.2505.67 / 9.8489.954.0090.0 (+0.1%)not run
0.1500.3005.91 / 11.8189.914.0090.6 (+0.7%)not run
0.1570.4006.18 / 15.7589.954.0091.9 (+2.1%)not run

Highlighted row: the gap nearest 0.130 mm (about one dielectric height) with width and gap both at least 0.10 mm.

100 Ω differential

Width, mmGap, mmW / gap, milZdiff, field solverεeff oddFormula3D FDTD
0.070 ⚠0.1002.76 / 3.9499.814.00106.4 (+6.6%)not run
0.085 ⚠0.1303.35 / 5.1299.864.00102.7 (+2.9%)not run
0.092 ⚠0.1503.62 / 5.9199.974.00101.7 (+1.7%)not run
0.1050.2004.13 / 7.8799.944.00100.5 (+0.5%)not run
0.1130.2504.45 / 9.84100.004.00100.6 (+0.6%)not run
0.1180.3004.65 / 11.81100.134.00101.3 (+1.2%)not run
0.1250.4004.92 / 15.7599.964.00102.5 (+2.5%)not run

Highlighted row: the gap nearest 0.130 mm (about one dielectric height) with width and gap both at least 0.10 mm.

Nearby cross-sections

What these numbers assume

Sources: computed here. Closed forms from IPC-2141A (2004) and Wheeler (1978). Method on the how it was checked page.