PCB Impedance Tables

50, 90 and 100 Ω trace width: stripline, 0.10 mm and 0.20 mm dielectric, Dk 4.5, 35 µm copper

Inner-layer trace between two solid planes: h1 = 0.10 mm below it, h2 = 0.20 mm from the trace base to the far plane, Dk 4.5 both sides, 35 µm (1 oz) copper.

Built by AI agents; confirm with your fab. These numbers are computed for the cross-section stated here, not for any fab's stackup. They are a starting point for a layout, not a guarantee of what your board will measure.

50 Ω single-ended

Width, mmWidth, milZ, field solverεeffFormula3D FDTD
0.073 ⚠2.8749.974.5050.0 (+0.0%)not run

90 Ω differential

Width, mmGap, mmW / gap, milZdiff, field solverεeff oddFormula3D FDTD
0.048 ⚠0.1001.89 / 3.9489.804.5098.8 (+10.0%)not run
0.063 ⚠0.1302.48 / 5.1289.914.5094.6 (+5.2%)not run
0.070 ⚠0.1502.76 / 5.9190.024.5093.1 (+3.5%)not run
0.082 ⚠0.2003.23 / 7.8789.944.5091.0 (+1.2%)not run
0.088 ⚠0.2503.46 / 9.8490.014.5090.4 (+0.5%)not run
0.091 ⚠0.3003.58 / 11.8190.184.5090.3 (+0.2%)not run
0.095 ⚠0.4003.74 / 15.7589.944.5089.9 (-0.1%)not run

⚠ Every row here is finer than 0.10 mm in width or gap.

100 Ω differential

Width, mmGap, mmW / gap, milZdiff, field solverεeff oddFormula3D FDTD
0.042 ⚠0.1301.65 / 5.1299.814.50106.2 (+6.4%)not run
0.048 ⚠0.1501.89 / 5.91100.094.50104.5 (+4.4%)not run
0.059 ⚠0.2002.32 / 7.8799.864.50101.8 (+1.9%)not run
0.065 ⚠0.2502.56 / 9.8499.834.50100.7 (+0.9%)not run
0.068 ⚠0.3002.68 / 11.81100.014.50100.4 (+0.4%)not run
0.071 ⚠0.4002.80 / 15.75100.064.50100.2 (+0.1%)not run

⚠ Every row here is finer than 0.10 mm in width or gap.

Nearby cross-sections

What these numbers assume

Sources: computed here. Closed forms from IPC-2141A (2004) and Wheeler (1978). Method on the how it was checked page.