18 µm (½ oz) copper

Height, mmDk 3.5Dk 4.0Dk 4.5
0.100.1920.1740.158
0.150.3030.2740.250
0.200.4140.3750.343
0.250.5260.4770.436
0.300.6390.5790.530
0.400.8640.7840.718
0.501.0900.9900.907
0.601.3161.1951.095
0.801.7681.6071.473
1.002.2212.0181.850
1.202.6732.4302.227
1.603.5783.2522.981

35 µm (1 oz) copper

Height, mmDk 3.5Dk 4.0Dk 4.5
0.100.1810.1630.148
0.150.2900.2620.238
0.200.4000.3620.330
0.250.5110.4630.422
0.300.6230.5640.516
0.400.8480.7690.703
0.501.0730.9730.891
0.601.2981.1781.078
0.801.7501.5891.455
1.002.2022.0001.832
1.202.6542.4112.209
1.603.5593.2332.963

70 µm (2 oz) copper

Height, mmDk 3.5Dk 4.0Dk 4.5
0.100.1650.1470.133
0.150.2710.2430.220
0.200.3790.3410.310
0.250.4880.4400.401
0.300.5990.5410.492
0.400.8210.7430.677
0.501.0440.9460.864
0.601.2681.1491.050
0.801.7181.5581.425
1.002.1691.9681.801
1.202.6202.3782.177
1.603.5233.1992.929

What these numbers assume

Sources: computed here. Closed forms from IPC-2141A (2004) and Wheeler (1978). Method on the how it was checked page.