PCB Impedance Tables

50, 90 and 100 Ω trace width: stripline, 0.50 mm and 0.50 mm dielectric, Dk 4.5, 18 µm copper

Inner-layer trace between two solid planes: h1 = 0.50 mm below it, h2 = 0.50 mm from the trace base to the far plane, Dk 4.5 both sides, 18 µm (½ oz) copper.

Built by AI agents; confirm with your fab. These numbers are computed for the cross-section stated here, not for any fab's stackup. They are a starting point for a layout, not a guarantee of what your board will measure.

50 Ω single-ended

Width, mmWidth, milZ, field solverεeffFormula3D FDTD
0.41816.4650.004.5049.6 (-0.8%)not run

90 Ω differential

Width, mmGap, mmW / gap, milZdiff, field solverεeff oddFormula3D FDTD
0.1310.1005.16 / 3.9490.044.50115.0 (+27.7%)not run
0.1790.1307.05 / 5.1290.074.50107.1 (+18.9%)not run
0.2080.1508.19 / 5.9190.054.50103.4 (+14.8%)not run
0.2690.20010.59 / 7.8789.954.5097.3 (+8.2%)not run
0.3150.25012.40 / 9.8490.044.5094.0 (+4.5%)not run
0.3510.30013.82 / 11.8189.984.5092.1 (+2.3%)not run
0.4030.40015.87 / 15.7589.984.5090.0 (-0.0%)not run

Highlighted row: the gap nearest 0.300 mm (about one dielectric height) with width and gap both at least 0.10 mm.

100 Ω differential

Width, mmGap, mmW / gap, milZdiff, field solverεeff oddFormula3D FDTD
0.085 ⚠0.1003.35 / 3.94100.104.50129.4 (+29.3%)not run
0.1220.1304.80 / 5.1299.944.50120.8 (+20.9%)not run
0.1440.1505.67 / 5.91100.044.50117.0 (+17.0%)not run
0.1930.2007.60 / 7.87100.064.50110.4 (+10.3%)not run
0.2340.2509.21 / 9.8499.974.50106.2 (+6.2%)not run
0.2650.30010.43 / 11.8199.984.50103.9 (+3.9%)not run
0.3120.40012.28 / 15.75100.014.50101.2 (+1.2%)not run

Highlighted row: the gap nearest 0.300 mm (about one dielectric height) with width and gap both at least 0.10 mm.

Nearby cross-sections

What these numbers assume

Sources: computed here. Closed forms from IPC-2141A (2004) and Wheeler (1978). Method on the how it was checked page.