PCB Impedance Tables

50, 90 and 100 Ω trace width: stripline, 0.40 mm and 0.50 mm dielectric, Dk 4.0, 35 µm copper

Inner-layer trace between two solid planes: h1 = 0.40 mm below it, h2 = 0.50 mm from the trace base to the far plane, Dk 4.0 both sides, 35 µm (1 oz) copper.

Built by AI agents; confirm with your fab. These numbers are computed for the cross-section stated here, not for any fab's stackup. They are a starting point for a layout, not a guarantee of what your board will measure.

50 Ω single-ended

Width, mmWidth, milZ, field solverεeffFormula3D FDTD
0.38615.2049.994.0049.6 (-0.8%)not run

90 Ω differential

Width, mmGap, mmW / gap, milZdiff, field solverεeff oddFormula3D FDTD
0.1060.1004.17 / 3.9489.964.00118.8 (+32.1%)not run
0.1580.1306.22 / 5.1290.024.00109.1 (+21.2%)not run
0.1890.1507.44 / 5.9189.994.00104.7 (+16.4%)not run
0.2520.2009.92 / 7.8790.004.0097.9 (+8.8%)not run
0.2990.25011.77 / 9.8489.964.0094.2 (+4.7%)not run
0.3350.30013.19 / 11.8189.984.0092.0 (+2.3%)not run
0.3820.40015.04 / 15.7590.064.0090.1 (+0.1%)not run

Highlighted row: the gap nearest 0.300 mm (about one dielectric height) with width and gap both at least 0.10 mm.

100 Ω differential

Width, mmGap, mmW / gap, milZdiff, field solverεeff oddFormula3D FDTD
0.063 ⚠0.1002.48 / 3.94100.014.00134.1 (+34.1%)not run
0.1020.1304.02 / 5.1299.954.00123.8 (+23.8%)not run
0.1260.1504.96 / 5.9199.994.00119.0 (+19.0%)not run
0.1780.2007.01 / 7.87100.024.00111.2 (+11.2%)not run
0.2190.2508.62 / 9.84100.044.00106.8 (+6.7%)not run
0.2510.3009.88 / 11.81100.034.00104.1 (+4.0%)not run
0.2970.40011.69 / 15.75100.034.00101.1 (+1.1%)not run

Highlighted row: the gap nearest 0.300 mm (about one dielectric height) with width and gap both at least 0.10 mm.

Nearby cross-sections

What these numbers assume

Sources: computed here. Closed forms from IPC-2141A (2004) and Wheeler (1978). Method on the how it was checked page.