PCB Impedance Tables

50, 90 and 100 Ω trace width: stripline, 0.30 mm and 0.50 mm dielectric, Dk 4.5, 18 µm copper

Inner-layer trace between two solid planes: h1 = 0.30 mm below it, h2 = 0.50 mm from the trace base to the far plane, Dk 4.5 both sides, 18 µm (½ oz) copper.

Built by AI agents; confirm with your fab. These numbers are computed for the cross-section stated here, not for any fab's stackup. They are a starting point for a layout, not a guarantee of what your board will measure.

50 Ω single-ended

Width, mmWidth, milZ, field solverεeffFormula3D FDTD
0.30512.0150.034.5049.9 (-0.2%)not run

90 Ω differential

Width, mmGap, mmW / gap, milZdiff, field solverεeff oddFormula3D FDTD
0.1230.1004.84 / 3.9490.044.50108.6 (+20.6%)not run
0.1630.1306.42 / 5.1290.064.50101.8 (+13.1%)not run
0.1860.1507.32 / 5.9190.064.5098.8 (+9.7%)not run
0.2310.2009.09 / 7.8790.054.5094.2 (+4.7%)not run
0.2640.25010.39 / 9.8490.034.5091.9 (+2.0%)not run
0.2880.30011.34 / 11.8190.004.5090.6 (+0.7%)not run
0.3200.40012.60 / 15.7590.054.5089.6 (-0.5%)not run

Highlighted row: the gap nearest 0.300 mm (about one dielectric height) with width and gap both at least 0.10 mm.

100 Ω differential

Width, mmGap, mmW / gap, milZdiff, field solverεeff oddFormula3D FDTD
0.081 ⚠0.1003.19 / 3.94100.134.50122.7 (+22.6%)not run
0.1130.1304.45 / 5.12100.004.50115.2 (+15.2%)not run
0.1320.1505.20 / 5.9199.934.50111.7 (+11.8%)not run
0.1700.2006.69 / 7.87100.044.50106.5 (+6.4%)not run
0.2000.2507.87 / 9.8499.914.50103.4 (+3.5%)not run
0.2220.3008.74 / 11.81100.034.50101.7 (+1.7%)not run
0.2520.4009.92 / 15.75100.044.50100.2 (+0.2%)not run

Highlighted row: the gap nearest 0.300 mm (about one dielectric height) with width and gap both at least 0.10 mm.

Nearby cross-sections

What these numbers assume

Sources: computed here. Closed forms from IPC-2141A (2004) and Wheeler (1978). Method on the how it was checked page.