PCB Impedance Tables

50, 90 and 100 Ω trace width: stripline, 0.30 mm and 0.40 mm dielectric, Dk 4.0, 18 µm copper

Inner-layer trace between two solid planes: h1 = 0.30 mm below it, h2 = 0.40 mm from the trace base to the far plane, Dk 4.0 both sides, 18 µm (½ oz) copper.

Built by AI agents; confirm with your fab. These numbers are computed for the cross-section stated here, not for any fab's stackup. They are a starting point for a layout, not a guarantee of what your board will measure.

50 Ω single-ended

Width, mmWidth, milZ, field solverεeffFormula3D FDTD
0.31312.3250.004.0049.6 (-0.7%)not run

90 Ω differential

Width, mmGap, mmW / gap, milZdiff, field solverεeff oddFormula3D FDTD
0.1490.1005.87 / 3.9490.014.00105.3 (+17.0%)not run
0.1920.1307.56 / 5.1289.934.0098.8 (+9.9%)not run
0.2150.1508.46 / 5.9189.954.0096.2 (+6.9%)not run
0.2590.20010.20 / 7.8789.954.0092.3 (+2.7%)not run
0.2890.25011.38 / 9.8490.034.0090.6 (+0.6%)not run
0.3110.30012.24 / 11.8190.044.0089.6 (-0.4%)not run
0.3390.40013.35 / 15.7590.054.0089.0 (-1.2%)not run

Highlighted row: the gap nearest 0.300 mm (about one dielectric height) with width and gap both at least 0.10 mm.

100 Ω differential

Width, mmGap, mmW / gap, milZdiff, field solverεeff oddFormula3D FDTD
0.1020.1004.02 / 3.9499.934.00119.4 (+19.5%)not run
0.1370.1305.39 / 5.1299.924.00112.2 (+12.3%)not run
0.1560.1506.14 / 5.91100.094.00109.3 (+9.2%)not run
0.1960.2007.72 / 7.8799.944.00104.3 (+4.3%)not run
0.2240.2508.82 / 9.8499.954.00101.9 (+1.9%)not run
0.2440.3009.61 / 11.81100.044.00100.7 (+0.6%)not run
0.2710.40010.67 / 15.75100.054.0099.5 (-0.6%)not run

Highlighted row: the gap nearest 0.300 mm (about one dielectric height) with width and gap both at least 0.10 mm.

Nearby cross-sections

What these numbers assume

Sources: computed here. Closed forms from IPC-2141A (2004) and Wheeler (1978). Method on the how it was checked page.