PCB Impedance Tables

50, 90 and 100 Ω trace width: stripline, 0.20 mm and 0.60 mm dielectric, Dk 4.5, 18 µm copper

Inner-layer trace between two solid planes: h1 = 0.20 mm below it, h2 = 0.60 mm from the trace base to the far plane, Dk 4.5 both sides, 18 µm (½ oz) copper.

Built by AI agents; confirm with your fab. These numbers are computed for the cross-section stated here, not for any fab's stackup. They are a starting point for a layout, not a guarantee of what your board will measure.

50 Ω single-ended

Width, mmWidth, milZ, field solverεeffFormula3D FDTD
0.2329.1350.004.5051.2 (+2.3%)not run

90 Ω differential

Width, mmGap, mmW / gap, milZdiff, field solverεeff oddFormula3D FDTD
0.1120.1004.41 / 3.9489.954.50104.0 (+15.6%)not run
0.1430.1305.63 / 5.1290.104.5098.4 (+9.2%)not run
0.1610.1506.34 / 5.9189.994.5095.8 (+6.5%)not run
0.1930.2007.60 / 7.8790.044.5092.5 (+2.8%)not run
0.2160.2508.50 / 9.8489.934.5090.9 (+1.1%)not run
0.2320.3009.13 / 11.8190.034.5090.3 (+0.4%)not run
0.2530.4009.96 / 15.7589.974.5090.1 (+0.2%)not run

Highlighted row: the gap nearest 0.200 mm (about one dielectric height) with width and gap both at least 0.10 mm.

100 Ω differential

Width, mmGap, mmW / gap, milZdiff, field solverεeff oddFormula3D FDTD
0.076 ⚠0.1002.99 / 3.9499.834.50117.3 (+17.5%)not run
0.1020.1304.02 / 5.1299.874.50110.8 (+10.9%)not run
0.1160.1504.57 / 5.9199.994.50108.2 (+8.2%)not run
0.1450.2005.71 / 7.8799.994.50104.0 (+4.0%)not run
0.1650.2506.50 / 9.84100.094.50102.1 (+2.0%)not run
0.1800.3007.09 / 11.8199.964.50101.2 (+1.2%)not run
0.2000.4007.87 / 15.7599.904.50100.6 (+0.7%)not run

Highlighted row: the gap nearest 0.200 mm (about one dielectric height) with width and gap both at least 0.10 mm.

Nearby cross-sections

What these numbers assume

Sources: computed here. Closed forms from IPC-2141A (2004) and Wheeler (1978). Method on the how it was checked page.