PCB Impedance Tables

50, 90 and 100 Ω trace width: stripline, 0.15 mm and 0.25 mm dielectric, Dk 4.0, 35 µm copper

Inner-layer trace between two solid planes: h1 = 0.15 mm below it, h2 = 0.25 mm from the trace base to the far plane, Dk 4.0 both sides, 35 µm (1 oz) copper.

Built by AI agents; confirm with your fab. These numbers are computed for the cross-section stated here, not for any fab's stackup. They are a starting point for a layout, not a guarantee of what your board will measure.

50 Ω single-ended

Width, mmWidth, milZ, field solverεeffFormula3D FDTD
0.1355.3150.064.0049.9 (-0.4%)not run

90 Ω differential

Width, mmGap, mmW / gap, milZdiff, field solverεeff oddFormula3D FDTD
0.076 ⚠0.1002.99 / 3.9490.144.00102.2 (+13.3%)not run
0.1020.1304.02 / 5.1289.954.0096.2 (+7.0%)not run
0.1140.1504.49 / 5.9190.114.0094.3 (+4.6%)not run
0.1360.2005.35 / 7.8789.934.0091.3 (+1.6%)not run
0.1480.2505.83 / 9.8490.124.0090.5 (+0.4%)not run
0.1560.3006.14 / 11.8190.084.0090.0 (-0.1%)not run
0.1650.4006.50 / 15.7589.994.0089.6 (-0.5%)not run

Highlighted row: the gap nearest 0.150 mm (about one dielectric height) with width and gap both at least 0.10 mm.

100 Ω differential

Width, mmGap, mmW / gap, milZdiff, field solverεeff oddFormula3D FDTD
0.048 ⚠0.1001.89 / 3.94100.104.00115.7 (+15.6%)not run
0.070 ⚠0.1302.76 / 5.1299.964.00108.8 (+8.9%)not run
0.081 ⚠0.1503.19 / 5.9199.964.00106.3 (+6.3%)not run
0.1010.2003.98 / 7.8799.944.00102.6 (+2.7%)not run
0.1130.2504.45 / 9.84100.004.00101.1 (+1.1%)not run
0.1210.3004.76 / 11.8199.884.00100.2 (+0.3%)not run
0.1290.4005.08 / 15.7599.924.0099.7 (-0.2%)not run

Highlighted row: the gap nearest 0.150 mm (about one dielectric height) with width and gap both at least 0.10 mm.

Nearby cross-sections

What these numbers assume

Sources: computed here. Closed forms from IPC-2141A (2004) and Wheeler (1978). Method on the how it was checked page.