PCB Impedance Tables

50, 90 and 100 Ω trace width: stripline, 0.10 mm and 0.60 mm dielectric, Dk 3.5, 35 µm copper

Inner-layer trace between two solid planes: h1 = 0.10 mm below it, h2 = 0.60 mm from the trace base to the far plane, Dk 3.5 both sides, 35 µm (1 oz) copper.

Built by AI agents; confirm with your fab. These numbers are computed for the cross-section stated here, not for any fab's stackup. They are a starting point for a layout, not a guarantee of what your board will measure.

50 Ω single-ended

Width, mmWidth, milZ, field solverεeffFormula3D FDTD
0.1385.4350.023.5052.9 (+5.7%)not run

90 Ω differential

Width, mmGap, mmW / gap, milZdiff, field solverεeff oddFormula3D FDTD
0.084 ⚠0.1003.31 / 3.9490.013.5099.2 (+10.3%)not run
0.1060.1304.17 / 5.1289.913.5094.2 (+4.8%)not run
0.1160.1504.57 / 5.9190.083.5092.7 (+2.9%)not run
0.1340.2005.28 / 7.8790.003.5090.9 (+1.0%)not run
0.1450.2505.71 / 9.8490.073.5090.6 (+0.6%)not run
0.1530.3006.02 / 11.8189.913.5090.7 (+0.9%)not run
0.1620.4006.38 / 15.7589.903.5091.6 (+1.9%)not run

Highlighted row: the gap nearest 0.130 mm (about one dielectric height) with width and gap both at least 0.10 mm.

100 Ω differential

Width, mmGap, mmW / gap, milZdiff, field solverεeff oddFormula3D FDTD
0.056 ⚠0.1002.20 / 3.94100.153.50112.5 (+12.3%)not run
0.076 ⚠0.1302.99 / 5.1299.873.50106.2 (+6.3%)not run
0.085 ⚠0.1503.35 / 5.91100.023.50104.3 (+4.3%)not run
0.1020.2004.02 / 7.8799.873.50101.8 (+1.9%)not run
0.1120.2504.41 / 9.84100.003.50101.3 (+1.3%)not run
0.1190.3004.69 / 11.8199.953.50101.5 (+1.5%)not run
0.1270.4005.00 / 15.75100.043.50102.4 (+2.4%)not run

Highlighted row: the gap nearest 0.130 mm (about one dielectric height) with width and gap both at least 0.10 mm.

Nearby cross-sections

What these numbers assume