PCB Impedance Tables

50, 90 and 100 Ω trace width: stripline, 0.10 mm and 0.25 mm dielectric, Dk 4.0, 18 µm copper

Inner-layer trace between two solid planes: h1 = 0.10 mm below it, h2 = 0.25 mm from the trace base to the far plane, Dk 4.0 both sides, 18 µm (½ oz) copper.

Built by AI agents; confirm with your fab. These numbers are computed for the cross-section stated here, not for any fab's stackup. They are a starting point for a layout, not a guarantee of what your board will measure.

50 Ω single-ended

Width, mmWidth, milZ, field solverεeffFormula3D FDTD
0.1144.4950.024.0050.6 (+1.1%)not run

90 Ω differential

Width, mmGap, mmW / gap, milZdiff, field solverεeff oddFormula3D FDTD
0.092 ⚠0.1003.62 / 3.9490.064.0094.2 (+4.6%)not run
0.1070.1304.21 / 5.1290.064.0091.8 (+1.9%)not run
0.1140.1504.49 / 5.9190.104.0091.0 (+1.0%)not run
0.1260.2004.96 / 7.8789.854.0090.2 (+0.3%)not run
0.1320.2505.20 / 9.8490.034.0090.3 (+0.3%)not run
0.1360.3005.35 / 11.8189.974.0090.3 (+0.4%)not run
0.1400.4005.51 / 15.7589.934.0090.5 (+0.7%)not run

Highlighted row: the gap nearest 0.130 mm (about one dielectric height) with width and gap both at least 0.10 mm.

100 Ω differential

Width, mmGap, mmW / gap, milZdiff, field solverεeff oddFormula3D FDTD
0.067 ⚠0.1002.64 / 3.94100.164.00106.2 (+6.1%)not run
0.081 ⚠0.1303.19 / 5.12100.014.00103.0 (+3.0%)not run
0.087 ⚠0.1503.43 / 5.91100.144.00102.2 (+2.0%)not run
0.098 ⚠0.2003.86 / 7.87100.054.00101.0 (+0.9%)not run
0.1040.2504.09 / 9.84100.144.00100.8 (+0.6%)not run
0.1080.3004.25 / 11.8199.994.00100.7 (+0.7%)not run
0.1120.4004.41 / 15.7599.874.00100.7 (+0.8%)not run

Highlighted row: the gap nearest 0.130 mm (about one dielectric height) with width and gap both at least 0.10 mm.

Nearby cross-sections

What these numbers assume

Sources: computed here. Closed forms from IPC-2141A (2004) and Wheeler (1978). Method on the how it was checked page.