PCB Impedance Tables

50, 90 and 100 Ω trace width: stripline, 0.10 mm and 0.20 mm dielectric, Dk 4.0, 35 µm copper

Inner-layer trace between two solid planes: h1 = 0.10 mm below it, h2 = 0.20 mm from the trace base to the far plane, Dk 4.0 both sides, 35 µm (1 oz) copper.

Built by AI agents; confirm with your fab. These numbers are computed for the cross-section stated here, not for any fab's stackup. They are a starting point for a layout, not a guarantee of what your board will measure.

50 Ω single-ended

Width, mmWidth, milZ, field solverεeffFormula3D FDTD
0.086 ⚠3.3949.944.0049.9 (-0.0%)not run

90 Ω differential

Width, mmGap, mmW / gap, milZdiff, field solverεeff oddFormula3D FDTD
0.060 ⚠0.1002.36 / 3.9490.054.0098.2 (+9.0%)not run
0.077 ⚠0.1303.03 / 5.1289.884.0093.8 (+4.3%)not run
0.084 ⚠0.1503.31 / 5.9190.044.0092.5 (+2.8%)not run
0.096 ⚠0.2003.78 / 7.8789.994.0090.8 (+0.9%)not run
0.1030.2504.06 / 9.8489.844.0090.0 (+0.2%)not run
0.1060.3004.17 / 11.8190.034.0090.0 (-0.0%)not run
0.1090.4004.29 / 15.7590.144.0090.0 (-0.2%)not run

Highlighted row: the gap nearest 0.130 mm (about one dielectric height) with width and gap both at least 0.10 mm.

100 Ω differential

Width, mmGap, mmW / gap, milZdiff, field solverεeff oddFormula3D FDTD
0.053 ⚠0.1302.09 / 5.12100.034.00105.8 (+5.7%)not run
0.060 ⚠0.1502.36 / 5.9199.964.00103.9 (+3.9%)not run
0.071 ⚠0.2002.80 / 7.87100.104.00101.7 (+1.5%)not run
0.077 ⚠0.2503.03 / 9.84100.194.00100.8 (+0.6%)not run
0.081 ⚠0.3003.19 / 11.8199.944.00100.2 (+0.2%)not run
0.084 ⚠0.4003.31 / 15.75100.004.00100.0 (+0.0%)not run

⚠ Every row here is finer than 0.10 mm in width or gap.

Nearby cross-sections

What these numbers assume

Sources: computed here. Closed forms from IPC-2141A (2004) and Wheeler (1978). Method on the how it was checked page.