PCB Impedance Tables

50, 90 and 100 Ω trace width: stripline, 0.10 mm and 0.10 mm dielectric, Dk 4.0, 35 µm copper

Inner-layer trace between two solid planes: h1 = 0.10 mm below it, h2 = 0.10 mm from the trace base to the far plane, Dk 4.0 both sides, 35 µm (1 oz) copper.

Built by AI agents; confirm with your fab. These numbers are computed for the cross-section stated here, not for any fab's stackup. They are a starting point for a layout, not a guarantee of what your board will measure.

50 Ω single-ended

Width, mmWidth, milZ, field solverεeffFormula3D FDTD
0.044 ⚠1.7350.164.0050.1 (-0.1%)not run

90 Ω differential

Width, mmGap, mmW / gap, milZdiff, field solverεeff oddFormula3D FDTD
0.040 ⚠0.1001.57 / 3.9490.114.0094.7 (+5.1%)not run
0.049 ⚠0.1301.93 / 5.1289.794.0091.7 (+2.1%)not run
0.052 ⚠0.1502.05 / 5.9189.974.0091.1 (+1.2%)not run
0.057 ⚠0.2002.24 / 7.8789.784.0090.0 (+0.3%)not run
0.059 ⚠0.2502.32 / 9.8489.854.0089.8 (-0.1%)not run
0.060 ⚠0.3002.36 / 11.8189.794.0089.6 (-0.2%)not run
0.060 ⚠0.4002.36 / 15.7590.144.0089.9 (-0.2%)not run

⚠ Every row here is finer than 0.10 mm in width or gap.

100 Ω differential

Width, mmGap, mmW / gap, milZdiff, field solverεeff oddFormula3D FDTD
0.041 ⚠0.2001.61 / 7.8799.854.00100.4 (+0.6%)not run
0.043 ⚠0.2501.69 / 9.8499.854.00100.0 (+0.1%)not run
0.044 ⚠0.3001.73 / 11.8199.764.0099.7 (-0.0%)not run
0.044 ⚠0.4001.73 / 15.75100.194.00100.1 (-0.1%)not run

⚠ Every row here is finer than 0.10 mm in width or gap.

Nearby cross-sections

What these numbers assume

Sources: computed here. Closed forms from IPC-2141A (2004) and Wheeler (1978). Method on the how it was checked page.