PCB Impedance Tables

50, 90 and 100 Ω trace width: stripline, 0.10 mm and 0.10 mm dielectric, Dk 3.5, 35 µm copper

Inner-layer trace between two solid planes: h1 = 0.10 mm below it, h2 = 0.10 mm from the trace base to the far plane, Dk 3.5 both sides, 35 µm (1 oz) copper.

Built by AI agents; confirm with your fab. These numbers are computed for the cross-section stated here, not for any fab's stackup. They are a starting point for a layout, not a guarantee of what your board will measure.

50 Ω single-ended

Width, mmWidth, milZ, field solverεeffFormula3D FDTD
0.054 ⚠2.1350.123.5050.0 (-0.2%)not run

90 Ω differential

Width, mmGap, mmW / gap, milZdiff, field solverεeff oddFormula3D FDTD
0.051 ⚠0.1002.01 / 3.9489.953.5093.7 (+4.2%)not run
0.059 ⚠0.1302.32 / 5.1290.173.5091.8 (+1.8%)not run
0.063 ⚠0.1502.48 / 5.9189.973.5090.8 (+0.9%)not run
0.068 ⚠0.2002.68 / 7.8789.933.5089.9 (-0.0%)not run
0.070 ⚠0.2502.76 / 9.8489.973.5089.7 (-0.3%)not run
0.071 ⚠0.3002.80 / 11.8190.003.5089.7 (-0.4%)not run
0.072 ⚠0.4002.83 / 15.7589.793.5089.4 (-0.4%)not run

⚠ Every row here is finer than 0.10 mm in width or gap.

100 Ω differential

Width, mmGap, mmW / gap, milZdiff, field solverεeff oddFormula3D FDTD
0.043 ⚠0.1301.69 / 5.1299.703.50102.2 (+2.5%)not run
0.046 ⚠0.1501.81 / 5.9199.963.50101.4 (+1.5%)not run
0.051 ⚠0.2002.01 / 7.8799.793.50100.1 (+0.3%)not run
0.053 ⚠0.2502.09 / 9.8499.783.5099.8 (-0.0%)not run
0.054 ⚠0.3002.13 / 11.8199.713.5099.6 (-0.1%)not run
0.054 ⚠0.4002.13 / 15.75100.113.5099.9 (-0.2%)not run

⚠ Every row here is finer than 0.10 mm in width or gap.

Nearby cross-sections

What these numbers assume

Sources: computed here. Closed forms from IPC-2141A (2004) and Wheeler (1978). Method on the how it was checked page.